potentially explosive environment. Not following these guidelines may result in serious injury
or death.

Caution

 

Do not disconnect the power supply wires and connectors from the

controller unless power has been switched off.

Caution

 

Do not disconnect I/O-side wires or connectors unless power has been

switched off or the area is known to be nonhazardous.

Caution

 

Do not remove modules unless power has been switched off or the area is

known to be nonhazardous.

Caution

 

Substitution of components may impair suitability for Class I, Division 2.

Caution

 

For Division 2 and Zone 2 applications, install the system in an enclosure

rated to at least IP54 as defined by IEC/EN 60079-15.

Caution

 

The USB port requires NI Industrial USB Extender Cable (152166-

xx

)

for hazardous locations. All cables must be used in a conduit or cable gland to wire
to a nonhazardous location. Do not disconnect a cable unless the cRIO-9068 is
powered off or the area is known to be nonhazardous.

Special Conditions for Hazardous Locations Use in Europe and
Internationally

The cRIO-9068 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12
ATEX 1202658X and is IECEx UL 14.0089X certified. Each device is marked   II 3G and is
suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤
70 °C.

Caution

 

You must make sure that transient disturbances do not exceed 140% of

the rated voltage.

Caution

 

The system shall only be used in an area of not more than Pollution

Degree 2, as defined in IEC/EN 60664-1.

Caution

 

The system shall be mounted in an ATEX/IECEx-certified enclosure with

a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.

Caution

 

The enclosure must have a door or cover accessible only by the use of a

tool.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements

2

  | 

ni.com

  | 

cRIO-9068 Getting Started Guide

Summary of Contents for cRIO-9068

Page 1: ...roduct misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is damaged return it to NI for repair Safety Gu...

Page 2: ...O 9068 is powered off or the area is known to be nonhazardous Special Conditions for Hazardous Locations Use in Europe and Internationally The cRIO 9068 has been evaluated as Ex nA IIC T4 Gc equipment...

Page 3: ...loyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requireme...

Page 4: ...t Figure 1 Kit Contents 3 2 1 1 cRIO 9068 with power connector 2 NI Driver Media 3 Getting Started Guide Installing Software on the Host Computer Before using the cRIO 9068 you must install the follow...

Page 5: ...C Series module 3 Align the C Series module with a slot and seat it in the slot until the latches lock in place Removing C Series Modules Verify that power is not connected to the I O connector s on t...

Page 6: ...following steps to ground the cRIO 9068 1 Attach the ring lug to the wire 2 Remove the grounding screw from the grounding terminal on the cRIO 9068 3 Attach the ring lug to the grounding terminal 4 Ti...

Page 7: ...powered from the V2 input Off The cRIO 9068 is powered off Caution Do not connect V2 to a DC mains supply or to any supply that requires a connecting cable longer than 3 m 10 ft A DC mains supply is a...

Page 8: ...m 1 8 lb in to 2 2 lb in of torque 7 Power on the primary power supply and optional secondary power supply Connecting the cRIO 9068 to the Host Computer or Network Complete the following steps to con...

Page 9: ...owing steps to set a system password Note The default username for the cRIO 9068 is admin There is no default password for the cRIO 9068 so you must leave the password field blank when logging in unti...

Page 10: ...gine from the software add ons Select any additional software to install If you plan on using the cRIO 9068 with the LabVIEW FPGA Module you can click Next Click NI Scan Engine if you plan on using th...

Page 11: ...s been improperly installed on the cRIO 9068 An error can occur when an attempt to upgrade the software is interrupted Reinstall software on the cRIO 9068 Refer to the Measurement Automation Explorer...

Page 12: ...ni com manuals NI cRIO 9068 User Manual ni com manuals C Series Getting Started Guides ni com manuals HARDWARE SOFTWARE APPLICATION SUPPORT Services ni com services Community ni com community Softwar...

Page 13: ...fication If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration NI corporate headquarters is located at 11500 North Mopac Expressway Aus...

Page 14: ...arty legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relev...

Reviews: