© National Instruments
|
1-15
USB 3.0 Port and Cable Strain Relief
The cDAQ chassis features a SuperSpeed USB 3.0 interface.
1
You can provide strain relief for
the USB cable by using the jackscrew on a locking USB cable to securely attach the cable to the
chassis.
Power Connector
Refer to the
NI cDAQ-9179 Specifications
for information about the power connector on the
cDAQ chassis.
Cables and Accessories
Table 1-2 contains information about cables and accessories available for the cDAQ chassis. For
a complete list of cDAQ chassis accessories and ordering information, refer to the pricing
section of the cDAQ-9179 product page at
ni.com
.
Removing C Series Modules from the Chassis
Complete the following steps to remove a C Series C Series module from the chassis.
1.
Make sure that no I/O-side power is connected to the C Series module. If the system is in a
nonhazardous location, the chassis power can be on when you remove C Series modules.
2.
Squeeze the latches on both sides of the module and pull the module out of the chassis.
1
You can use standard USB 2.0 cables and/or Hi-Speed USB 2.0 ports on your computer with the
cDAQ chassis, but the chassis speed will be limited to Hi-Speed USB 2.0 standards (480 Mb/s).
Table 1-2.
cDAQ Chassis Cables and Accessories
Accessory
Part Number
Desktop Mounting Kit for 14-Slot CompactDAQ
784302-01
Panel Mount Kit for 14-Slot CompactDAQ
784303-01
NI 9916 DIN Rail Kit
780982-01
Locking USB 3.0 cable, (1 m and 2m length)
157930A-01/02
2-pos screw terminal kit for power supply connection, qty 4
780702-01
NI PS-15 Power Supply
(24 VDC, 5 A, 100-120/200-240 VAC input)
781093-01
Desktop Power Supply (12 VDC, 3.33 A, 90-240 VAC)
784301-01
Summary of Contents for cDAQ-9179