BNC-2110 Installation Guide

Relative humidity ................................... 5 to 90% noncondensing

Safety

The BNC-2110 meets the requirements of the following standards for 
safety and electrical equipment for measurement, control, and laboratory 
use:

IEC 61010-1, EN 61010-1

UL 3111-1, UL 61010B-1

CAN/CSA C22.2 No. 1010.1

Note

For UL and other safety certifications, refer to the product label or to 

ni.com

.

Electromagnetic Compatibility

Emissions ............................................... EN 55011 Class A at 10 m

FCC Part 15A above 1 GHz

Immunity ................................................ EN 61326:1997 + A2:2001, 

Table 1

EMC/EMI............................................... CE, C-Tick, and FCC Part 15 

(Class A) Compliant

Note

For EMC compliance, you 

must

 operate this device with shielded cabling.

CE Compliance

This product meets the essential requirements of applicable European 
Directives, as amended for CE marking, as follows:

Low-Voltage Directive (safety) ............. 73/23/EEC

Electromagnetic Compatibility
Directive (EMC) .................................... 89/336/EEC

Note

Refer to the Declaration of Conformity (DoC) for this product for any additional 

regulatory compliance information. To obtain the DoC for this product, click 

Declarations 

of Conformity Information 

at 

ni.com/hardref.nsf/

. This Web site lists the DoCs by 

product family. Select the appropriate product family, followed by your product, and a link 
to the DoC appears in Adobe Acrobat format. Click the Acrobat icon to download or read 
the DoC.

Summary of Contents for BNC-2110

Page 1: ...rminal block with 30 pins for signal connections and a 68 pin I O connector that connects to the E Series S Series and waveform generation Multifunction DAQ devices The BNC 2110 is ideal for simplifyi...

Page 2: ...onnecting the BNC 2110 to Your DAQ Device 1 Place the BNC 2110 near the host computer or use the optional DIN rail mounting kit which you can order from National Instruments For more information about...

Page 3: ...r off any external signals connected to the BNC 2110 before you power off your computer Caution The BNC 2110 is not designed for input voltages greater than 42 V even if a user installed voltage divid...

Page 4: ...lences table in the E Series Help at ni com manuals Figure 2 BNC 2110 Front Panel 1 Floating Source FS Ground Referenced Source GS Switch 2 BNC Connectors 3 Terminal Block Retaining Screws 4 Terminal...

Page 5: ...nnectors you use depends on your DAQ device and your application Table 2 BNC 2110 Connector Signal Descriptions Front Panel BNC Connectors Signal Description AI 0 1 Differential Analog Input channels...

Page 6: ...the switch to either the floating or ground referenced source position For best results use the ground referenced source position labeled GS to avoid ground loops Refer to your DAQ device documentatio...

Page 7: ...on the BNC 2110 front panel These terminals and their associated BNC connectors give you the flexibility to choose up to two additional digital timing signals For example if an application requires a...

Page 8: ...neral Purpose Counters 0 and 1 respectively CTR 1 OUT Counter 1 Output This is the output from General Purpose Counter 1 USER 1 User defined 1 Connected to USER 1 BNC this terminal provides a user def...

Page 9: ...Part 15 Class A Compliant Note For EMC compliance you must operate this device with shielded cabling CE Compliance This product meets the essential requirements of applicable European Directives as am...

Page 10: ...mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the pat...

Reviews: