Chapter 2
Configuration and Installation
2-8
©
National Instruments Corporation
Figure 2-2.
Daisy-Chaining Multiple AMUX-64T Boards
Table 2-6 lists the valid multiple-board configurations for both
single-ended and differential modes.
When you connect two or more AMUX-64T boards together, the
multiplexers on different boards must be enabled at different times.
Therefore, each board is assigned a different channel address range
determined by the configuration of switch U12. The switch settings for
each board configuration are given in the following sections.
Table 2-6.
Channel Ranges for Multiple AMUX-64T Boards
Number of External
Multiplexer Boards
Channel Range
Single-Ended
Channel Range
Differential
1
64
32
2
128
64
4
256
128
MIO Board
Daisy-Chaining
Cable
50-Pin Ribbon Cable
Cascade up to four AMUX-64T boards for a total of 256
single-ended (128 differential) analog input channels
Mounting holes for
standoffs or for
mounting in a
rack-mount kit or
anywhere else
Ex5 V
AISENSE
16 single-ended
(8 differential)
analog input channels.
Total of 64 single-
ended per board.