cabling clearances. For a complete list of cabling clearances for C Series modules, visit
and enter the Info Code
crioconn
.
Figure 6. NI 9155 Cabling Clearance
Cabling
Clearance
Ambient Temperature
Measure the ambient temperature at each side of the NI 9155, 63.5 mm (2.50 in.) from the side
and 50.8 mm (2.00 in.) forward from the rear of the NI 9155, as shown in the following figure.
Figure 7. NI 9155 Ambient Temperature Location
50.8 mm
(2.00 in.)
1
50.8 mm
(2.00 in.)
63.5 mm
(2.50 in.)
1
63.5 mm
(2.50 in.)
1. Location for measuring the ambient temperature
Mounting the Device on a DIN Rail
You can use the NI DIN rail mounting kit to mount the NI 9155 on a standard 35-mm DIN
rail.
What to Use
•
NI 9155
•
Screwdriver, Phillips #2
•
NI DIN rail mounting kit, 779018-01
–
DIN rail clip
–
M4x50 screw (x2)
NI 9155 User Manual
|
© National Instruments
|