Hardware Installation
Install the NI 7330 motion controller in any open compatible expansion slot in the PXI or PCI
system. Appendix A,
, lists the typical power required for each controller.
The following instructions are for general installation. Consult the computer user manual or
technical reference manual for specific instructions and warnings.
Caution
The NI 7330 motion controller is a sensitive electronic device shipped in
an antistatic bag. Open only at an approved workstation and observe precautions for
handling electrostatic-sensitive devices.
Note
When adding or removing a motion controller, you must be logged on with
administrator-level access. After you have restarted the system, you may need to
refresh Measurement & Automation Explorer (MAX) to view the new controller.
PXI Motion Controllers
1.
Power off and unplug the chassis.
Caution
To protect yourself and the computer from electrical hazards, the
computer
must
remain unplugged until the installation is complete.
2.
Choose an unused peripheral slot and remove the filler panel.
3.
Touch a metal part on the chassis to discharge any static electricity.
4.
Insert the NI 7330 motion controller into the PXI slot as shown in Figure 2-1. Use the
injector/ejector handle to fully secure the device into place.
Figure 2-1.
Installing an NI 73xx Motion Controller in a PXI Chassis
1
PXI Chassis
2
PXI System Controller
3
NI 73xx Motion Controller
4
Front-Panel Mounting Screws
5
Module Guides
6
Power Switch
3
PXI-1000B
5
6
2
4
1