background image

 

LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments 
Corporation. Refer to the 

Trademark Information 

at

 

ni.com/trademarks

 for other National Instruments trademarks. Other product and 

company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments 
products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National 

Instruments Patent Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party legal 

notices in the NI-DAQmx Readme. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 for the National 

Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. 

© 2006–2012 National Instruments. All rights reserved.

374435C

Nov12

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

A Declaration of Conformity (DoC) is our claim of compliance with the 
Council of the European Communities using the manufacturer’s 
declaration of conformity. This system affords the user protection for 
electromagnetic compatibility (EMC) and product safety. You can obtain 
the DoC for your product by visiting 

ni.com/certification

. If your 

product supports calibration, you can obtain the calibration certificate for 
your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access 

the branch office Web sites, which provide up-to-date contact information, 
support phone numbers, email addresses, and current events.

Summary of Contents for 653 Series

Page 1: ...patible with the NI 654x and NI 655x digital pattern generator analyzer devices For best signal integrity NI recommends using the NI 6535 6536 6537 and 6535B6536B 6537B devices with newer accessories...

Page 2: ...familiarize you with different aspects of the device The titles and location of the documents vary based on the driver that supports the NI device but you should have the following types of documenta...

Page 3: ...1 NI 653x Cable Adapter Parts Locator Diagram 1 Enclosure Base 2 Jacksockets M2 5 Screw 2 56 Socket 3 68 Pin DAQ Connector 4 Enclosure Top Cover 5 M2 5 6 mm Phillips Flathead Countersunk Screws 6 Term...

Page 4: ...ot liable for damage resulting from improper connections Refer to Figure 2 as you complete the following steps to install the cable adapter 1 Insert the cable into the cable adapter 2 Tighten the cabl...

Page 5: ...enclosure complete the following steps 1 Remove the screws from the cable adapter enclosure top cover as shown in Figure 3 Figure 3 Remove Screws from the Enclosure 2 Remove the enclosure top cover No...

Page 6: ...36B and NI 6537 6537B VHDCI connector are connected to a 6 position screw terminal PFI 0 7 from the NI 6533 6534 68 pin DAQ connector are connected to an 8 position screw terminal PFI channels must be...

Page 7: ...NI 653x cable adapter Figure 4 NI 653x Signal Connections Note Refer to the help file for your device for information about the number of available DIO channels on your device DIO 20 31 or PFI_0 may n...

Page 8: ...68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO 31 GND DIO 29 GND DIO 27 GND DIO 25 RESERVED DIO 23 GND DIO 21 GND DIO 19 GND DIO 17 GND DIO 15 GND...

Page 9: ...39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 5 V PFI 2 PFI 6 PFI 0 PFI 4 PFI 5 PFI 1 PFI 7 PFI 3 P0 0 GND P0 3 P0 4 GND P0 7 P1 0 P1 1 GND R GND GND P1 6...

Page 10: ...7 P1 0 7 P2 0 7 or P3 0 7 on a 68 pin DAQ connector PFI 0 5 Programmable functional interface PFI channels 0 through 5 6 position screw terminal J4 GND Ground reference for signals RESERVED These cha...

Page 11: ...d with the NI high speed DIO device NI is not liable for any damage resulting from such signal connections Table 3 shows the relationship between PFI channels and the termination sockets Note Refer to...

Page 12: ...e compatibility between an NI 6533 6534 and an NI 6535 6536 6537 or NI 6535B 6536B 6537B where the fixture is configured to work with the NI 6533 6534 Without changing the fixture setup the adapter an...

Page 13: ...g table A burst handshaking example using the NI 6533 6534 can be coded in LabVIEW as shown in Figure 8 Figure 8 NI 6533 6534 Burst Handshaking Application Table 4 Example Connections VHDCI NI 6535 65...

Page 14: ...he NI 653x cable adapter connections and provide compatibility with the previous application using an NI 6535 6536 6537 or an NI 6535B 6536B 6537B instead of an NI 6533 6534 Figure 9 NI 653x Burst Han...

Page 15: ...mm 2 47 2 73 0 66 in I O connectors 68 pin VHDCI connector 6 position screw terminal 8 position screw terminal 68 pin DAQ connector Recommended wire gage 22 26 AWG Recommended torque for screw termina...

Page 16: ...ource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engin...

Reviews: