Machine Operation
Fax: 763-535-8255
12
UNPACKING
When unpacking the machine, please check that the following accessories are included:
•
Hose with end fittings
• Handle
• Floor nozzle
• Extra bags
If any of the above mentioned parts are missing, please contact your distributor or our sales representative.
Assemble the front wheels using the bolt, washer and nut that are included in the package.
FUNCTION
•
The machine is designed for sucking and separating dry, non-combustible dust with an explosion limit value of 0.1mg/m3.
• The motor is started by the switch, which has three positions:
0: Motor off 1: Motor on (2: Autostart function, only 230V version).
• Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is slowed down by the cyclone
and coarse dust particles are separated out, partly by centrifugal force and partly by gravity. Air and finer particles then pass
through the double filter system where separation is made. The machine is designed for filter cleaning by reverse air pulse.
• The sepa
rated dust accumulates in the cyclone until the machine is switched off, when it drops through the bottom flap into the
plastic bag.
MACHINE USE
Connect the electric plug to an outlet with the correct voltage.
• Before use, the user must be trained in handling the machine and the hazardous dust.
•
The filter must be cleaned from time to time. This must be done before changing the plastic bag and can also be done when
the work is complete or when there is poor suction.
PURGE VAC
To maximize airflow, the operator must periodically purge the machine
as airflo
w lessens. Follow purging instruction below:
1. Shut off vac.
2. Remove vacuum hose from hose inlet (Ref 1)
3. Cover hose inlet with plastic cap suspended from machine (Ref 1)
NOTE: IF PLASTIC CAP IS NOT AVAILABLE, CAREFULLY COVER INLET WITH THE PALM OF YOUR HAND.
USE PROPER SAFETY EQUIPMENT.
4. Turn vac
ON.
5.
Slowly press handle valve a minimum of 3-4 times to engage jet pulse/purge (Ref 2)
6. Turn vac
OFF.
7. Remove plastic cap from inlet.
8. Connect vacuum hose to inlet.
9. Once
the dust collector has been properly purged, the air flow gauge should
view in the green position. If red, continue to purge or change filters.
Ref 1
Ref 2
Summary of Contents for 3472