background image

Installation Guide for NHPA Split-System Heat Pumps

19

HEATING & A/C EQUIPMENT

NATIONAL

COMFORT

PRODUCTS

®

539 Dunksferry Road 

|

 Bensalem, PA 19020 

|

 215-244-1400 

1-800-523-7138 

Fax: 215-244-9579

A Division of National Refrigeration & Air Conditioning Products, Inc.

 

1.

   National Comfort Products warrants to its customers that its product shall be free from defects in material and 

workmanship under normal use and regular service and maintenance as follows:
 

COMPRESSORS:

 For five years from the date of original installation.  

  

ALL OTHER PARTS:

 For all other parts except the Compressor, for two years from the date of original installation.    

 

Customer must register the product within 60 days of purchase.  If Customer cannot adequately document date of 

installation, then, for purposes of determining the warranty period, the date of installation shall be 60 days from the date of 

purchase. The 2 year parts warranty is effective for units purchased after January 1, 2016.

 

2.

   This warranty does not extend to any damages or losses due to misuse, accident, abuse, neglect, normal wear and 

tear, negligence (other than National Comfort’s), unauthorized modification or alteration; use beyond rated capacity; unsuitable 

power sources or environmental conditions; improper installation, repair, handling, maintenance or application; damage as a 

result of fire, wind, floods, lightning, or corrosive conditions; or any other cause not the fault of National Comfort.  By way of 

example and without limitation, the following do not constitute a defect in workmanship and materials and are not covered by this 

warranty: slugging of liquid refrigerant or oil, unstable line voltage, lightning, operating without proper lubrication, and operating 

without factory provided safeties.  Any installation that impairs or impedes air flow negatively impacts performance and causes 

premature equipment failure that voids this warranty.  For example, installation behind a brick façade or the addition of a brick 

pattern façade, i.e. pigeon holes impedes air flow and shall void this warranty. 

 

3.

   

SOLE WARRANTY 

 

 

The warranties identified herein constitute National Comfort’s sole and exclusive warranties with respect to the goods 

and are in lieu of and exclude all other warranties, express or implied, arising by operation of law or otherwise, including without 

limitation, merchantability and fitness for a particular purpose whether or not the purpose or use has been disclosed to National 

Comfort in specifications, drawings or otherwise, and whether or not National Comfort’s goods are specifically designed and/or 

manufactured by National Comfort for Customer’s use or purpose.

 

4.

   

LIMITATION OF REMEDY

 

The sole and exclusive remedy for breach of any warranty hereunder (other than the warranty provided herein) shall be 

limited to repair, replacement, credit or refund of the purchase price to distribution as set forth herein.  

 

National Comfort is not responsible for any other item including but not limited to local transportation, freight, removal of 

any compressor or part, any labor associated therewith, service or diagnosis calls, refrigerant, or costs for returning any defective 

compressor or part.  

 

5.

  

LIMITATION OF WARRANTY

 

NATIONAL COMFORT MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, ORAL OR WRITTEN, RELATED 

TO THE GOODS, INCLUDING ANY WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, 

WHICH ARE EXPRESSLY DISCLAIMED.   NATIONAL COMFORT SHALL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, OR 

CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY CAUSE WHATSOEVER, INCLUDING, WITHOUT LIMITATION, LOSS 

OF USE, COMMERCIAL PROFITS, OR CUSTOMER GOODWILL, AND ANY OTHER CLAIMS BASED ON CONTRACT OR 

TORT, WHETHER OR NOT ARISING FROM NATIONAL COMFORT’S NEGLIGENCE. 
 

National Comfort shall not be liable for damages caused by delay in performance and the remedies of Customer set forth 

in this agreement are exclusive.  In no event, regardless of the form of the claim or cause of action (whether based in contract, 

infringement, negligence, strict liability, other tort or otherwise) shall National Comfort’s liability to Customer and/or its customers 

exceed the price paid by Customer for the specific goods or portion of the goods provided by National Comfort giving rise to the 

claim or cause of action, and Customer shall indemnify and hold harmless National Comfort for any damages incurred by National 

Comfort in excess thereof.  Customer agrees that in no event shall National Comfort’s liability to Customer and/or its customers 

extend to include incidental, consequential, or punitive damages.

 THRU-THE-WALL CONDENSING UNIT & HEAT PUMP  

LIMITED WARRANTY

Continued on next page

Summary of Contents for NHPA 3000 Series

Page 1: ...lation National Comfort Products A Division of National Refrigeration Air Conditioning Products Inc 539 Dunksferry Road Bensalem PA 19020 215 244 1400 1 800 523 7138 Fax 215 639 1674 HEATING A C EQUIP...

Page 2: ...Leak Checking Page 8 Evacuation Electrical Connections Page 9 High Voltage and Power Supply Page 10 Start Up Sequence of Operations Page 10 Refrigerant Charging Page 12 Maintenance Checkout Procedure...

Page 3: ...y grounded Failure to do so can cause electrical shock resulting in severe personal injury or death WARNING These instructions are intended as an aid to qualified licensed service personnel for proper...

Page 4: ...uctions do not cover all variations in systems or provide for every possible contingency to be met in connection with the installation Should further information be desired or should particular proble...

Page 5: ...ved by NCP to maintain unit performance and warranty Care must be taken to locate coil intake side of unit away from loose debris that may clog intake 7 If the unit is mounted behind a decorative gril...

Page 6: ...ted Isolate lines from all ductwork Minimize the number of 90 turns Maximum Allowable Liquid Line Pressure Drop 50 PSI Subtract 43 PSI for each foot of Liquid Lift if any Do Not Exceed this value when...

Page 7: ...he heat pump should not block access to major components Refrigerant lines should not be in direct contact with the floor or ceiling joists Use insulated or suspension type hangers When refrigerant li...

Page 8: ...valent length of refrigerant lines exceeds 50 ft Leak Checking Leak checking of refrigerant line braze joints and evaporator unit using dry nitrogen 1 Install service port cap of the vapor line servic...

Page 9: ...onnected Electrical Connections NOTE Make certain that the volts hertz and phase correspond to that specified on the unit rating plate and that the service provided by the utility is sufficient to han...

Page 10: ...l stop On a call for heating the room heat pump thermostat makes circuits R G and R Y Circuit R G energizes the indoor blower motor relay Circuit R Y energizes the contactor starting the compressor an...

Page 11: ...nder the coil must be piped per item number 12 under the Unit Location Considerations section of this manual System Charge Adjustment Temperature Measurements Check the outdoor temperatures Subcooling...

Page 12: ...Operation Compressor Damage Do not operate with a restricted suction Do not operate with the low pressure cut out bridged Do not operate compressor without enough system charge to maintain at least 0...

Page 13: ...ng for leaks and suction line insulation Improper insulation can cause condensate water damage 6 Pressure and temperature readings of high and low side of system should be checked for proper super hea...

Page 14: ...Reading between Terminals C R __________ 5 Compressor Winding OHM Reading between Terminals R S __________ 6 Compressor Winding OHM Reading between Terminals C Ground __________ 7 Compressor Winding O...

Page 15: ...Installation Guide for NHPA Split System Heat Pumps 15...

Page 16: ...00 19 000 ELECTRICAL 208 230 60 1 12 13 78 20 208 230 60 1 10 16 8 25 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 9 0 56 3 10 9 62 9 RLA Amps LRA Amps FAN MOTOR 0 25 1500 1 4 0...

Page 17: ...5 HP 1500 RPM 14270049 14270049 10 14 Prop Fan 14214033 14214033 11 Motor Mount 14270102 14270102 12 Access Panel 3000 14256780 14256780 13 Top Panel 3000 14256303 14256303 14 Right Side Panel 1425631...

Page 18: ...ndard AHRI 270 2008 As an option we offer an Insulated Sound Cover for installation over the inside cover of the unit Sound Without Indoor Cover 70 4 dba Standard AHRI 350 2008 Sound With Indoor Cover...

Page 19: ...all other warranties express or implied arising by operation of law or otherwise including without limitation merchantability and fitness for a particular purpose whether or not the purpose or use has...

Page 20: ...ial number whichever occurs first then Customer may take the compressor to any Authorized Copeland Distributor for replacement of said compressor If the defect is reported to National Comfort after on...

Page 21: ...ta Limitations All installations should factor a proper building heat gain along with appropriate duct sizing and electrical supply wiring to be figured by a professional engineer familiar with local...

Page 22: ...____________________ ________________________________________________________________________ ________________________________________________________________________ _________________________________...

Page 23: ...____________________ ________________________________________________________________________ ________________________________________________________________________ _________________________________...

Page 24: ...Installation Guide NHPA Heat Pump 14299144 7 2016 National Comfort Products 539 Dunksferry Road Bensalem PA 19020 5908 800 523 7138 Fax 215 638 1674 HEATING A C EQUIPMENT NATIONAL COMFORT PRODUCTS...