DIP SWITCH

 

 

A Micro Dip Switch is located on the underneath side of 

Tone Alert. 

It is a 4 position Dip Switch which is provided for the purposes of: 

1.

 

Changing the Frequency of the Alert Tone 

2.

 

Changing the ON to OFF Cadence of the Alert Tone 

 

SETTINGS: 

 

Dip Switch SW1   - 

 

Is Not Used   

 

 

Dip Switch SW2  - 

 

Is for the Output Tone   

 

 

ON   

 

 

  400Hz Tone (normal ring tone) 

 

OFF  

 

 

1200Hz Tone (higher pitched tone) 

 

 

Dip Switches  - 

 

 

Is for the Output Cadence 

 

SW3  

SW4 

 

ON   

ON   

2 seconds ON, 4 seconds OFF 

 

OFF  

ON   

2 seconds ON, 2 seconds OFF 

 

ON   

OFF  

4 seconds ON, 4 seconds OFF 

 

OFF  

OFF  

Full Time ON 

 
 

 

 

Summary of Contents for TONE ALERT

Page 1: ...Page 1 Natcomm TONE ALERT ACCESSORY For Technical Assistance Please Ph 07 5596 5128 ...

Page 2: ...one Alert is NOT a Loud Ringer itself If that solution is required please contact Natcomm to request a Siren Alert Tone Alert uses a Plastic Mylar speaker so that it can be used outdoors under cover It is designed to be used as a convenient Wall Mount or Desk Mount unit to Alert local users of Incoming Calls or other Telephone Line conditions It has a volume control pot located on the underside of...

Page 3: ...Page 3 Natcomm INSTALLATION WITH NATCOMM DEVICE ...

Page 4: ...witching device and Tone Alert should both display green 4 When the switching device is activated Tone Alert will emit an Alert Tone 5 The tone that is emitted can be adjusted to suit your requirements as follows by using the dip switches on the underneath side i Change the Frequency of the Alert Tone ii Change the Cadence of the Alert Tone iii Refer to page 7 for Dip Switch Settings 6 External po...

Page 5: ...Page 5 Natcomm INSTALLATION WITH SEPARATE SWITCH ...

Page 6: ...nnect the supplied 12V power supply or your own 12V 500mA minimum power supply to the 12V power socket of Tone Alert and turn power on The LED should display green 4 When the Dry Contact switch is activated Tone Alert will emit an Alert Tone 5 The tone that is emitted can be adjusted to suit your requirements as follows by using the dip switches on the underneath side i Change the Frequency of the...

Page 7: ...ency of the Alert Tone 2 Changing the ON to OFF Cadence of the Alert Tone SETTINGS Dip Switch SW1 Is Not Used Dip Switch SW2 Is for the Output Tone ON 400Hz Tone normal ring tone OFF 1200Hz Tone higher pitched tone Dip Switches Is for the Output Cadence SW3 SW4 ON ON 2 seconds ON 4 seconds OFF OFF ON 2 seconds ON 2 seconds OFF ON OFF 4 seconds ON 4 seconds OFF OFF OFF Full Time ON ...

Page 8: ...ature of the problem This Warranty shall not apply to any unit which has been subject to alteration modification abuse negligence accident external voltage lightning surge or used in any manner contrary to these instructions The obligation is solely to repair or replace the product The warrantor is not liable for any incidental or consequential damages due to such defects The user is responsible f...

Reviews: