DESCRIPTION 

Ring  Delay  Switch 

is  designed  to  DELAY  the  ring  from  an  Incoming  Telephone  Call 

connecting to a specific device for between 1 and 8 rings.

 

 

This Product is ideal for the following applications :

 

 

 

Delaying Answer by an Answering Machine

 

 

 

Delaying Answer by a Modem Based Device

 

 

 

Will  allow  for  a  Second  Fax  Machine  to  Answer  a  Fax  Call,  after  a  set 
delay, if the First Fax Machine cannot answer for any  reason.

 

 

 

Delay the Ringing of Specific Telephones

 

 

Ring  Delay  Switch 

is  transparent  in  operation  and  will  not  affect  the  normal 

operation of the telephone line that it is connected  to.

 

 

Incoming  and  outgoing  telephone  calls  to  and  from  the  Telephone  Line  will  take  place 
exactly as they always have.

 

 

Incoming  calls  will  connect  to  all  devices  connected  to  the  Telephone  Line  out  port, 
without delay.

 

 

Incoming  calls  will  connect  to  all  devices  connected  to  the  Ring  Delay  port,  after  a  set 
delay of 1-8 rings, if the call has not been answered first.

 

 

Ring  Delay  Switch 

will  automatically  connect  all  attached  Telephone  Devices  to  the 

telephone line as soon as they are activated by the user (ie picking up a receiver to dial, 
or sending a transmission).

 

 

An  EXCLUSION  FACILITY  is  provided  to  ensure  that  a  Device  connected  to  the  Ring 
Delay Port  cannot interfere  or ‘Barge-In’ on a Device connected to the Telephone Line 
Out port, if it is in use.

 

 

Similarly,  a  Device  connected  to  the Telephone Line  Out  cannot  interfere  or  ‘Barge-In’ 
on a Device connected to the Ring Delay port, if it is in use.

 

 

Ring Delay Switch is provided with a 2 YEAR FACTORY WARRANTY.

 

Summary of Contents for Ring Delay Switch

Page 1: ...NATCOMM USA LLC Responsible Supplier Code NC RING DELAY SWITCH USER GUIDE For Technical Assistance email the Manufacturers direct info natcomm us ...

Page 2: ...Page 2 Natcomm INSTALLATION DIAGRAM ...

Page 3: ...take place exactly as they always have Incoming calls will connect to all devices connected to the Telephone Line out port without delay Incoming calls will connect to all devices connected to the Ring Delay port after a set delay of 1 8 rings if the call has not been answered first Ring Delay Switch will automatically connect all attached Telephone Devices to the telephone line as soon as they ar...

Page 4: ...LINE OUT port of Ring Delay Switch using the cable supplied with the device 4 RING DELAY DEVICE CONNECTION The device which DOES require Ring Delay Connect this device to the RING DELAY port of Ring Delay Switch using the cable supplied with the device 5 SET DIP SWITCHES TO DESIRED SETTINGS To set the required Ring Delay by setting the position of Dip Switches 2 3 and 4 which are located on the un...

Page 5: ...ition Ring Delay Switch 2 Switch 3 Switch 4 Required 1 Ring ON ON ON 2 Rings OFF ON ON 3 Rings ON OFF ON 4 Rings OFF OFF ON 5 Rings ON ON OFF 6 Rings OFF ON OFF 7 Rings ON OFF OFF 8 Rings OFF OFF OFF Important Note In limited circumstances you may need to set Switch 1 to the ON position See page 6 for more detail ...

Page 6: ... ON position When Dip Switch 1 is set to the ON position Ring Delay Switch will leave your Telephone device connected to your telephone line when your line is not in use It will then remove it from the telephone line whenever you attempt to make an outgoing call with a Telephone Device connected to the Telephone Line Out port ie a device that does not require Ring Delay AND also each time there is...

Page 7: ... controller A Telephone Technician will connect the incoming line direct to the TELEPHONE LINE IN Port and then connect the TELEPHONE LINE OUT port to the PBX Telephone System The RING DELAY DEVICE will then connect to the RING DELAY port An EXCLUSION FACILITY is provided to ensure that the connected devices can not interfere with each other This means that if one device is in operation the other ...

Page 8: ... return your unit along with the proof of purchase date and a written statement about the nature of the problem The Manufacturers obligation is solely to repair or the product The product may be replaced at the discretion of the Manufacturer The warrantor is not liable for any incidental or consequential damages due to such defects This Warranty shall not apply to any unit which has been subject t...

Reviews: