National Combustion Co., Inc.
Page 4
9
Fuel
N = Natural Gas
P = Propane
10
Altitude
A = 0–10,000 feet
11
Location
C = Indoor and Outdoor
12
Firing Mode
K = Two-stage
13
Revision
1 = First version of design
14
Heat Exchanger
B = Glass-lined cast iron / copper / bronze trim
(std. on water heaters)
C = Glass-lined cast iron / copper
(std. on boilers, n/a on water heaters)
K = Bronze / copper
N = Glass-lined cast iron / cupro-nickel
(n/a on water heaters)
P = Glass-lined cast iron / cu-nickel / bronze trim
S = Bronze / cupro-nickel
15
Option Code
X = Standard unit
J = CSD-1, FM, IRI, IL
16
Pump Options
X = No Pump
H = Pump mounted F85V, hard water pump
N = Pump mounted (any), normal water pump
S = Pump mounted F85V, soft water pump
1.3 Warranty
NATCO Heating Systems’ appliances are covered
by a limited warranty. Owners should submit online
warranty registration at
www.National Combustion.com
.
All warranty claims must be made to an authorized
National Combustion Co. representative or directly to
Customer Service. Claims must include the serial
number and model (this information can be found on the
rating plate), installation date, and name of the installer.
Shipping costs are not included in the warranty
coverage.
Some accessory items are shipped in separate
packages. Verify receipt of all packages listed on the
packing slip. Inspect everything for damage immediately
upon delivery, and advise the carrier of any shortages or
damage. Any such claims should be filed with the
carrier. The carrier, not the shipper, is responsible for
shortages and damage to the shipment whether visible or
concealed.
1.4 Dimensions
See Figures 1 and 2.
1.5 Locating the Appliance
The appliance should be located to provide
clearances on all sides for maintenance and inspection. It
should not be located in an area where leakage of any
connections will result in damage to the area adjacent to
the appliance or to lower floors of the structure.
When such a location is not available, it is
recommended that a suitable drain pan, adequately
drained, be installed under the appliance.
The appliance is design certified by CSA-
International for installation on combustible flooring; in
basements; in closets, utility rooms or alcoves
. Fire
Coil 85 Boilers or Water Heaters must never be
installed on carpeting.
The location for the appliance
should be chosen with regard to the vent pipe lengths
and external plumbing. The unit shall be installed such
that the gas ignition system components are protected
from water (dripping, spraying, rain, etc.) during
operation and service (circulator replacement, control
replacement, etc.). When vented vertically, the Fire Coil
85 must be located as close as practical to a chimney or
outside wall. If the vent terminal and/or combustion air
terminal terminate through a wall, and there is potential
for snow accumulation in the local area, both terminals
should be installed at an appropriate level above grade.
The dimensions and requirements that are shown in
Table 1
should be met when choosing the locations for
the appliance.
1.6 Locating Pump-Mounted Water Heater
with Respect to Storage Tank(s)
For best results, a pump-mounted Fire Coil 85
water heater should be located within 15 feet (4.6m) of
the storage tank(s). The pump is sized for 30 feet (9.1m)
of piping.
If the appliance must be installed with longer piping
runs, then larger diameter pipe or tubing shall be used.
Consult the factory for assistance.
1.7 Locating Pump-Mounted Boiler with
REQUIRED
RECOMMENDED
APPLIANCE
CLEARANCE FROM
SERVICE ACCESS
SURFACE
COMBUSTIBLE MATERIAL
CLEARANCE
inches
cm
inches
cm
Left Side
1
2.5
24
61
Right Side
1
2.5
24
61
Top
1
2.5
12
30
Back
1
2.5
**
12**
30**
Front
1
2.5
36
91
Vertical
(Category 1)
6*
15.2*
Vent
Horizontal
per UL1738 venting
(Category 3)
system supplier’s
Vent
instructions
*1" (2.5cm) when b-vent is used.
**When vent and/or combustion air connects to the back, recommended
clearance is 36" (91cm).
Table 1. Clearances.
Summary of Contents for Fire Coil 85
Page 23: ...Fire Coil 85 500 2000 Page 23 Figure 19 Fire Coil 85 500 750 Connection Diagram ...
Page 24: ...National Combustion Co Inc Page 24 Figure 20 Fire Coil 85 1000 Connection Diagram ...
Page 25: ...Fire Coil 85 500 2000 Page 25 Figure 21 Fire Coil 85 1250 2000 Connection Diagram ...
Page 37: ...Fire Coil 85 500 2000 Page 37 Figure 23 Sheet Metal Components ...
Page 38: ...National Combustion Co Inc Page 38 Figure 24 Internal Components ...