background image

1

About the Simulator

The 

Life

/

form

®

 Auscultation Trainer Simulator features 28 heart and lung conditions selected by the 

instructor by wireless remote control. The simulator duplicates human conditions as closely as modern 

plastics and electronic technology allows.

The remote control does not have to be pointed directly at the manikin or SmartScope™ to operate. One 

remote control will operate multiple sets of SmartScopes™ and manikins simultaneously. Great for group 

instruction. The range of the remote control is up to 100 feet.
LF01172U includes amplified speaker. LF01142U does not include amplified speaker.

List of Components

 

  Trainer Torso 

 Batteries

 

  Remote Control 

  Colored Dots

 

  SmartScope™ with Single- & Dual-Use Headpieces 

  Hard Carry Case

 

  Amplifier/Speaker System (LF01189U included in LF01172U only)

Set Up

 

  Remove product from packaging.

 

  Install batteries first in the remote and then in  

    the SmartScope™. (See figure 1.)

 

  Retain packaging for storage.

General Instructions for Use

 

1.

  To begin using the Auscultation Trainer, press  

    the red power button. This turns on the remote  

    control and sends a signal to activate the  

    SmartScope™ as well. After the unit is activated,  

    the display will be in the “status” mode, dis- 

    playing the current menu settings for the 

    heart and lung conditions.
 

2.

  To select a new condition, press either the  

    heart or lung button. This will put the display  

    into the menu mode. The user can select a condition by either using the number buttons, or by  

    viewing the conditions in sequence using the scroll button
 

3.

  After the condition is selected, press the enter button to activate.

The remote control can be programmed to these 

heart conditions:

01  Normal Heart 

02  Aortic regurgitation 

03  Pulmonary stenosis 

04  Mitral stenosis 

05 Holosystolic 

06 Mid-systolic 

07  S3 Gallop 

08  S4 Gallop 

09  Systolic click 

10 ASD 

11 PDA 

12 VSD

The remote control can be programmed to these 

lung conditions:

01  Normal lung 

02 Vesicular 

03 Wheezes 

04  Mono wheeze 

05  Fine crackle 

06  Coarse crackle 

07  Ronchi crackle 

08 Stridor 

09 Cavernous 

10 Bronchovesicular 

11 Bronchial 

12  Pulmonary edema 

13 Infant 

14  Friction rub 

15 Egophony 

16 Pectoriloquy

+

+

+

+

Figure 1

NP030_00_LF01142_LF01172_AuscultationSmartScope.indd   3

4/13/17   3:22 PM

Summary of Contents for Life/form LF01172U

Page 1: ...Auscultation Trainer and SmartScope LF01142U LF01172U Instruction Manual Products by Nasco NP030_00_LF01142_LF01172_AuscultationSmartScope indd 1 4 13 17 3 22 PM ...

Page 2: ...NP030_00_LF01142_LF01172_AuscultationSmartScope indd 2 4 13 17 3 22 PM ...

Page 3: ...tation Trainer press the red power button This turns on the remote control and sends a signal to activate the SmartScope as well After the unit is activated the display will be in the status mode dis playing the current menu settings for the heart and lung conditions 2 To select a new condition press either the heart or lung button This will put the display into the menu mode The user can select a...

Page 4: ...rry case in a temperature controlled environment avoiding extreme hot or cold temperatures Replace batteries regularly for optimum working condition It is recommended that batteries are removed when not in use Avoid getting ink on torso simulator or practice boards Ink will transfer indelible stains Troubleshooting When preparing to use your SmartScope and remote use batteries that are fully charg...

Page 5: ...3 MHz may cause sound selection issues or existing sounds to stop or restart Reset the remote by turning it off briefly then on again and select a different Heart or Lung sound Connecting an external speaker Insert the jack end of the speaker cord into the top of the SmartScope See figure 2 Using an external speaker When using an amplifier speaker no sounds will be heard through the SmartScope ear...

Page 6: ... Erb s point Fourth left intercostal space Apex First left intercostal space Tracheal Site Posterior Lung Sites Anterior Heart and Lung Sites lower left sternum Second right intercostal space aortic Midaxillary Lower anterior 4 NP030_00_LF01142_LF01172_AuscultationSmartScope indd 6 4 13 17 3 22 PM ...

Page 7: ...5 Holosystolic Murmur Normal Normal Normal Normal Patient has mitral regurgitation frequent premature ventricular con tractions Murmur is crescendo de cresendo with late peaking Soft S3 in mid diastole 6 Midsystolic Murmur Normal Normal Normal Normal Patient with hypertrophic cardimyop athy has a murmur that begins after S1 and ends before S2 7 S3 Gallop Normal Normal Normal Normal Patient has a r...

Page 8: ... Crackle 6 Coarse Crackle Coarse Crackle Coarse Crackle Coarse Crackle Coarse Crackle 7 Ronchi Ronchi Ronchi Ronchi Ronchi 8 Stridor Stridor Stridor Stridor Lower Volume Stridor Lower Volume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular Normal Vesicular Normal Vesicular 11 Bronchial Bronchial Bronchial Normal Vesicular Normal Vesicular 12 Pulmona...

Page 9: ...NP030_00_LF01142_LF01172_AuscultationSmartScope indd 9 4 13 17 3 22 PM ...

Page 10: ...luxe Plus CRiSis Auscultation Manikin 901 Janesville Avenue P O Box 901 Fort Atkinson Wisconsin 53538 0901 1 800 558 9595 eNasco com Email lifeform eNasco com LF01220U LF01200U LF01992U LF03968U LF01992U Other Available Simulators Anterior Auscultation Practice Board with Case and SmartScope Adult Infant Auscultation Training Set Auscultation Manikin LF01220U LF01200U LF03968U NP030_00_LF01142_LF0...