Nasco Healthcare Child CRiSis Starter Torso Instruction Manual Download Page 5

5

simulator doesn’t have the standard snap connectors. (Please 

see accessories at the end of this section).

Once your manikin is connected to your patient simulator, 

you will be able to pick up the ECG waves either through 

the monitor hook-ups on the skin or through the two disks 

attached to the skin on the defibrillation sites.

These disks will enable you to pick up the ECG waves using 

either the “Quick Look” paddle option or directly through gel 

pads, just like on a realpatient.

It is possible to use AED gel pads with the cable connectors 

built into the gel — the same ones you use on patients.

In an effort to help you save money, Nasco offers a set of 

training buttons that will correspond to your particular AED 

unit. These buttons are sold separately, and can be used over 

and over again. They come as a set with the patient  

simulator adapters. 

Set up

2

Available Supplies
LF03631U
  Replacement Headskin  

 

with Airway

LF03627U   Replacement Lung Set
LF03628U   Replacement Stomach
LF03644U   Pump Spray Lubricant
LF09919U   Nasco Cleaner

Defibrillation Chest Skin
About the Simulator
The 

Life

/

form

®

 Child Defibrillation 

Chest Skin has been designed for the 

Child 

CR

i

S

is

 manikin to enable you, 

the customer, to safely practice defi-

brillation.

The Child Defibrillation Chest Skin 

has been designed to absorb a maxi-

mum of 360 joules of energy*. 

Although capable of absorbing 360 

joules, we recommend that the small-

est energy level possible be used 

while training with the skin.
The Child Defibrillation Chest Skin will 

enable you to practice defibrillation 

using manual, semiautomatic, and 

automatic external defibrillators 

(AEDs). When using any one of these 

types of defibrillators in training, 

always follow the recommended 

operating procedures for that particu-

lar defibrillator. 

List of Components
  •  Defibrillation Chest Skin with  

  Load Box and Four Lead Snap  

  Cable Connector
*Note: 360 joules is the maximum 

energy level that Nasco recommends 

administering to the defibrillation 

chest skin. Energy levels in excess of 

360 joules may cause irreparable 

damage to the chest skin, circuitry, 

and patient simulator being used — 

thus voiding Nasco’s warranty and 

endangering your equipment. Nasco 

assumes no liability for damage or 

injury that may be caused by the use 

and/or misuse of this equipment. All 

normal safety precautions for defibril-

lation training should be followed, and 

energy levels should be minimized. 

Nasco did not design nor intend this 

defibrillation chest skin to be used as 

anything other than a training appara-

tus for defibrillation.

Connecting Your Patient Simulator

Connect the four lead snap cable to 

your patient simulator.
Nasco has designed the Child 

CR

i

S

is

 

System to be compatible with a vari-

ety of patient simulators. This is possi-

ble via the standard four lead snap 

cable. 

(See figure 2.) If your patient 

simulator has only two output posts, 

the red and black leads must be con-

nected to the patient simulator.

Figure 2

Summary of Contents for Child CRiSis Starter Torso

Page 1: ...Child CRiSis Starter Torso LF03674 INSTRUCTION MANUAL Child CRiSis Starter Torso LF03674 Instruction Manual Products by Nasco Starter Torso...

Page 2: ...piglottis arytenoids false and true vocal cords cricoid ring tracheal rings trachea esophagus lungs and stomach The Child Airway Management Trainer Head allows you to practice oral digital and nasal i...

Page 3: ...y levels in excess of 360 joules may cause irreparable damage to the chest skin circuitry and patient simulator being used thus voiding Nasco s warranty and endangering your equipment Nasco assumes no...

Page 4: ...t Skin The Child CRiSis Starter Torso allows you to simulate resuscitation and practice airway management skills including intubation and suction and perform defibrillation and CPR Airway Management T...

Page 5: ...360 joules we recommend that the small est energy level possible be used while training with the skin The Child Defibrillation Chest Skin will enable you to practice defibrillation using manual semia...

Page 6: ...lator is plugged in and working properly Problem ECG wave is inverted Solution Recheck the position of the red and black lead snaps on the patient simulator Note If the defibrillation chest skin is no...

Page 7: ...t to either repair or replace affected parts or the entire unit at their sole discre tion after investigating and reviewing the actual product and the damage In most instances a digital photo of the p...

Page 8: ...Nasco Healthcare 16 Simulaids Drive Saugerties NY 12477 1 833 NASCOHC 627 2642 info nascohealthcare com www nascohealthcare com NP 050 01 RV 06 21 2021 Nasco Healthcare...