background image

7. CONSTRUCTION OF THE STEAM ROOM:

 

-  The steam room must be well insulated, especially the ceiling, through which most of the steam 

  escapes. Because of the humidity, it is recommended the insulation be covered with a moisture 

  resistant material, for instance aluminum foil.  Wood must always be used to panel the walls. 

 

8. PROTECTIVE BARRIER:

 

-   A protective barrier may be built around the heater if necessary. In this case, you should 

  definitely adhere to the minimum clearances from structures made of flammable materials.  

9. IMPORTANT ADDITIONAL INSTRUCTIONS:

-   You should be careful in the vicinity of the hot heater, because the stones and 

  metal parts of the heater may cause burns. 

-   Only a small amount of water should be thrown onto the heater stones, because 

  the steaming water is scalding hot. 

-   This equipment is not to be used by children or people whose physical and 

  psychological traits, mental functions, lack of experience or knowledge may hinder 

  the safe operation of the equipment, if the person who is responsible for safety 

  cannot supervise them or instruct them in the use of the equipment. 

-   Children may not be left unsupervised and they should be supervised to make sure 

  they do not play with the equipment. 

-   Always inspect the steam room before plugging in the heater. 

-   The improperly filed stone container is a fire hazard. 

-   Covering the stove will cause a fire hazard.

 

When measuring the insulation barrier of the heater, some leakage may occur, which is 

caused by the humidity that has seeped into the insulation material during transport 

or warehousing. The moisture will evaporate after the heater is heated a few times. 

Do not connect the power supply for the electric heater through a fault current protection!  

10. CONNECTION SCHEME:

400V 3N~ 

-t 

X1-2 

X1-1 

X1-3  X1-4 

Disp. 

VA1  VA2  VA3 

YKS. 

A1  A2 

NTC 

B1  B2 

NTC 

+12V 

CTL 

-- 

J7 
J8 

L1 

L1 

CTL  L2 

L2 

PE 

PE 

L3 

L3 

Black

Brown

Red

Orange

Control of the electric heating

Display

NTC 

Overheating 

protection

Control unit

ON/OFF 
Switch

Red

Yellow

Blue

White

Summary of Contents for STONET 907230

Page 1: ...m room space shown in table 1 Table 1 Installation information for STONET heaters The minimum height of the steam room and minimal safety clearances are shown in table 1 Make sure that the surface ont...

Page 2: ...l the sensor in the area lined in Figure 2 Install the temperature sensor on the wall with the screws included in the delivery 2 pcs 2 9 x 16 The wiring for the temperature sensor can be embedded Conn...

Page 3: ...an be removed to enable easier piling of the stones in the lower part When piling the stones make sure that the resistors do not get bent and that the circulation of air is sufficient Stones 5 10 cm i...

Page 4: ...ing mode and any subsequent settings of the power on time will only affect the current heating session When the SET button is depressed the yellow LED will flash and an array of zeros will be displaye...

Page 5: ...100 C and the heater is desired to be switched on for 2 5 hours at a time 1 Switch on the power using the I O button 2 Depress the SET button the yellow LED flashes 3 Depress the SET button a second...

Page 6: ...ity of fresh air The fresh air is directed through a ca 100 mm diameter duct preferably directly from the outside to above the heater There must be a space of at least 1 000 mm between the temperature...

Page 7: ...ck of experience or knowledge may hinder the safe operation of the equipment if the person who is responsible for safety cannot supervise them or instruct them in the use of the equipment Children may...

Reviews: