Effect Group effect
Sauna room
Minimal safety clearances to the heater
CABLES
FUSES
Volume
Height
on the
sides
at the
front
at the
front
to the
ceiling
Power
unit
Connecting cable*)
mm
2
Front
fuse
Group fuse
min max
min
A **)
B **)
C **)
D **)
Group1
Group2
Group1 Group2
kW
kW
kW
m
3
m
3
cm
cm
cm
cm
cm
mm
2
A
A
A
18
9
9
18
30
220
15
15
15
150
5 x 10
5x2.5
5x2.5
3x35
16
16
21
9
12
24
36
220
15
15
15
150
5 x 10
5x2.5
5x4
3x35
16
25
24
12
12
27
40
220
15
15
15
150
5 x 16
5x4
5x4
3x50
25
25
27
12
15
30
46
220
15
15
15
150
5 x 16
5x4
5x6
3x50
25
25
30
15
15
40
56
220
15
15
15
150
5 x 16
5x6
5x6
3x50
25
25
**) See figure 1
*) Connected with rubber cable, type H07RN-F or corresponding cable
Effect
Sauna room
Minimal safety clearances to the heater
Connection*)
Volume
Height
on the
sides
at the
front
at the
front
to the
ceiling
400 V 3N~
Fuses
min max
min
A **)
B **)
C **)
D **)
kW
m
3
m
3
cm
cm
cm
cm
cm
mm
2
A
9
8
12
210
10
10
10
140
5x2,5
3x16
10,5
9
15
210
10
10
10
140
5x2,5
3x16
12
10
18
210
10
10
10
140
5x4
3x20
15
14
24
210
10
10
10
140
5x6
3x25
**) See figure 1 *) Connected with rubber cable, type H07RN-F or corresponding cable
Table 1. Installation data for stoves
Fig. 1: Safety distances for stoves
min A
min B
min C
min D
10cm
KÄYTTÖOHJE
min A
min B
min C
min D
10cm
min A
min B
min C
min D
10cm
min A
min B
min C
min D
10cm
KÄYTTÖOHJE
min A
min B
min C
min D
10cm
min A
min B
min C
min D
10cm
9–15 kW
18–30 kW