materials is 1000 mm or any other distance stipulated 
in the manufacturer’s instructions.

2.3.2 Non-combustible structure

If the wall is masonry or other structure classified as non-
combustible, it is sufficient to have a 50 mm air gap be-
tween the upright surfaces and the wall.

2.4 Smoke flue

A smoke flue of the sauna heater must meet the require-
ments of class T600 irrelevant of the material of the smoke 
flue. The minimum recommended draft of the smoke flue 
is 12 Pa. 

A modular smoke flue must meet the requirements of class 
T600 and provided with CE-marking. When installing a 
modular smoke flue safety clearances stipulated in the in-
stallation manual of the smoke flue shall be followed. The 
minimum recommended diameter of a modular smoke flue 
is 120 mm. The weight of the smoke flue must not cause 
load on the sauna heater. The sauna heater should be con-
nected to a separate smoke flue. A smoke flue made of 
bricks must be at least the so-called half-brick smoke flue.

2.5 Ventilation

Ventilation of the steam room should be sufficiently effi-
cient and should function so that fresh incoming air is rout-
ed as close to the sauna heater as possible. Also proper 
air circulation has to be provided in the steam room during 
using the sauna so that air can exit from under the sauna 
bench or from under the door of the washing room (suf-
ficient gap).

Extraction fans working in the same room as the firebox 
may cause problems. Incoming air inlets should be located 
so that they do not get blocked (for instance because of 
snow). A firebox needs combustion air in a volume of 6–10 
m3 per kilo of fired wood. The diameter of the ventila-
tion opening must be at least 100 mm. Forced air system 
should be built according to the design prepared by the 
designer of the heating, water and ventilation systems.

After using the sauna there shall be a possibility to ventilate 
and dry the sauna rooms so that air exits via the upper part 
of the steam room.

Summary of Contents for Kota Kuru 14

Page 1: ...Kota Kuru 14 14 VS and 20 sauna heaters Installation user and maintenance instructions version 1 4 Made by NARVI Oy Finland GB...

Page 2: ...2 GB Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en...

Page 3: ...a heater 8 3 1 Preheating 8 3 2 Regulation of the height 8 3 3 Connection with the smoke flue 8 3 4 Installation of a door and changing of the opening direction of the door 8 3 5 Sauna heater stones 8...

Page 4: ...you lack sufficient knowl edge if you are not allowed to use a sauna because of your health condition or you are under the influence of substances causing intoxication Sauna heaters must not be used...

Page 5: ...ust be taken into account Ignorance of safety clearances causes a fire hazard If required additional information can be obtained from the regional branch of the rescue board 2 3 1 Structure made of co...

Page 6: ...heater The sauna heater should be con nected to a separate smoke flue A smoke flue made of bricks must be at least the so called half brick smoke flue 2 5 Ventilation Ventilation of the steam room sh...

Page 7: ...connection with the smoke flue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota sto...

Page 8: ...ock air openings and stones must not be stacked over the top surface of the sauna heater The recommended quantity of stones in the sauna heater is shown in clause 1 1 The use of stones with a regular...

Page 9: ...be slippery 4 Using the sauna heater 4 1 Firewood Both hardwood and softwood can be used to heat the sauna heater The use of chipboard fibreboard painted or impregnated wood waste or plastic is prohi...

Page 10: ...f firewood so that not to damage the smoke flue 4 3 Steam water Use normal domestic water for steam water Quality requirements for domestic water humus content 12 mg l iron content 0 2 mg l calcium co...

Page 11: ...eater may change colour during heating This is a charac teristic feature of stainless steel and is not covered by warranty The warranty period starts form the moment that the goods are delivered to th...

Page 12: ...t Back Side Ceiling 250 mm 250 mm 1 350 mm Pass Pass NPD Pass Pass 0 57 Pass 69 12 Pa 13 kW 7 5 kg Pass Pass 370 C Narvi Oy 13 EN 15821 2010 Multi firing sauna stoves fired by natural wood logs for sp...

Reviews: