![NARVI Oy Finland NC20 Installation, User And Maintenance Instructions Download Page 44](http://html2.mh-extra.com/html/narvi-oy-finland/nc20/nc20_installation-user-and-maintenance-instructions_4531787044.webp)
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC24
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O₂
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 200 mm
Pass
Pass
NPD
Pass
Pass (0,17 %)
Pass (65 %)
12 Pa
17 kW
11 kg
Pass
Pass
463 C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC16
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O₂
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 250 mm
Pass
Pass
NPD
Pass
Pass (0,07 %)
Pass (70 %)
12 Pa
16 kW
7 kg
Pass
Pass
387 C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC20 VS
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O₂
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 225 mm
Pass
Pass
NPD
Pass
Pass (0,12 %)
Pass (67 %)
12 Pa
16 kW
9 kg
Pass
Pass
425 C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC20
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O₂
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 225 mm
Pass
Pass
NPD
Pass
Pass (0,12 %)
Pass (67 %)
12 Pa
16 kW
9 kg
Pass
Pass
425 C
NAR
VI Oy pidättää oikeudet tuotteisiin tuleviin muutoksiin.
Narvi Oy
Yrittäjäntie 1
27230 Lappi, Finland
Tel. +358 207 416 740
www.narvi.fi
Summary of Contents for NC20
Page 38: ...38 RU 1000 2 3 2 50 100 2 4 600 12 600 120 2 5 6 10 m3 100...
Page 39: ...39 39 RU 3 3 1 1 2 3 2 25 3 3 25 1 1 3 4 7 3 5 NC 20 VS 1 1 8...
Page 40: ...40 RU 3 6 Kota 10 15 1 1 3 7 NARVI NC16 NC20 NC20VS NC24...
Page 42: ...42 RU 2 3 4 1 10 9 1 2 1 3 10 20 4 3 12 0 2 100 0 05 4 4 4 5...
Page 43: ...43 43 RU 4 6 5 6 7 Narvi 2 2...