Yrittäjäntie 14, FI-27230 Lappi • tel. +358 0207 416 740 • fax +358 0207 416 743 • www.narvi.fi/en
12
GB
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC24
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O2
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 200 mm
Pass
Pass
NPD
Pass
Pass (0,15 %)
Pass (64 %)
12 Pa
19 kW
12 kg
Pass
Pass
476 ˚C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC16
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O2
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 250 mm
Pass
Pass
NPD
Pass
Pass (0,07 %)
Pass (70 %)
12 Pa
16 kW
7 kg
Pass
Pass
387 ˚C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC20 VS
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O2
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 200 mm
Pass
Pass
NPD
Pass
Pass (0,11 %)
Pass (67 %)
12 Pa
18 kW
10 kg
Pass
Pass
432 ˚C
Narvi Oy
12
EN 15821:2010
Multi-firing sauna stoves fired by natural wood logs
for space heating in residential buildings
Narvi NC20
Fire safety (initiation, risk to adjacent
elements)
Pass
- including declared safety
distances to combustible
materials:
Emission of combustible products
Durability
Surface temperature
Release of dangerous substances
Cleanability
Flue gas temperature
Mechanical resistance
Thermal output and
Energy efficiency, as:
- carbon monoxide emission at 13 % O2
- total efficiency
- flue draught
- refuelling loads
- thermal output
(i.e. nominal space heating output)
Back
Side
Ceiling
150 mm
150 mm
1 200 mm
Pass
Pass
NPD
Pass
Pass (0,11 %)
Pass (67 %)
12 Pa
18 kW
10 kg
Pass
Pass
432 ˚C