5. Soot fire

IN CASE OF SOOT FIRE (ALSO IF IT 
HAS ALREADY BEEN EXTINGUISHED) 
ALWAYS INFORM THE EMERGENCY 
CENTRE!

!

If  you  detect  soot  fire  in  the  smoke  flue,  close  the  ash 
drawer and the door of the firebox immediately. After soot 
fire  and  before  the  next  use  of  the  sauna  let  a  chimney-
sweeper  check  the  condition  of  the  smoke  flue  and  the 
sauna heater.

 

6. Frequently Asked 

Questions

The sauna heater is drafting poorly
•  The sauna heater has not been used in a long time; the 

smoke flue and sauna heater are damp.

•  The sauna heater is not receiving sufficient air; there is 

a downdraft in the sauna caused by ventilation.

•  The sauna heater has not been cleaned in a long time.
•  The ash drawer is closed or full of ashes.
•  Leakage in the connective flue.

The sauna does not heat up properly
•  The firewood is damp.
•  The sauna heater has insufficient power.
•  The sauna heater or smoke flue is drafting poorly.
•  The stones of the sauna heater are dirty or crumbling or 

stacked too tightly.

•  There are too many stones or there are too many small 

stones.

The sauna heater smells
•  The sauna heater has not been properly heated the first 

time it was done.

•  The stones of the sauna heater were not washed before 

loading.

•  Fat or other dirt has accumulated on the stones.
•  Steam water is not clean.

 

7. Warranty

Pursuant to consumer protection legislation Narvi sau-
na heater’s warranty period is two years. The warranty 
covers normal family use provided use, installation and 

maintenance meet the requirements stipulated in the 
instructions.

The warranty period starts form the moment that the goods 
are delivered to the end user. The supplier is not liable in any 
way for any defects within the framework of the warranty or 
other defects that appear later than two (2) years after the 
delivery of the goods to the client. The supplier may decide 
to  either  repair  the  defective  goods  or  replace  the  defec-
tive goods at its own direction. The warranty does not cover 
possible transport, unloading or installation costs or other 
corresponding costs. A receipt from the company selling the 
product serves as proof of warranty.

The client must check the goods immediately after delivery. 
The client must submit a written notice of claims to the sup-
plier within two (2) weeks of discovering the defect or the 
moment when the defect should have been discovered.

Do not modify the structure of this product. With this prod-
uct you can only use manufacturer-recommended accesso-
ries! Failure to comply with the manual or fire safety regula-
tions can result in a fire or damage to the sauna heater. More 
detailed information about the fire safety regulations can be 
obtained from the regional branch of the rescue board, for 
instance.

The  product  shall  be  carefully  inspected.  Improper  use  of 
the  product  is  for  instance  wrong  adjustment  of  the  draft, 
too large a quantity of firewood burnt in the firebox, too long 
heating time, wrong arrangement of stones (too much or too 
tight) and use of salty water ( for instance sea water). The 
warranty does not cover damages caused by improper use 
of the sauna heater.

 

4.6 Disposal

For disposal take the sauna heater to a public waste recy-
cling centre.

Summary of Contents for NC 16

Page 1: ...GB Made by NARVI Oy Finland Narvi NC 16 20 20 VS 24 sauna heaters Installation user and maintenance instructions Version 1 0...

Page 2: ...Yritt j ntie 14 FI 27230 Lappi tel 358 0207 416 740 fax 358 0207 416 743 www narvi fi en 2 GB...

Page 3: ...ation of the height 7 3 3 Connection with the smoke flue 7 3 4 Installation of a door and changing of the opening direction of the door 7 3 5 Installation of a water tank faucet models with a water ta...

Page 4: ...e sauna heater preferably on the lower part of the cover of the sauna heater Do not heat the sauna heater if you lack sufficient knowl edge if you are not allowed to use a sauna because of your health...

Page 5: ...R UN DERFLOOR HEATING A Kota installation base must be installed under the sauna heater which will protect the floor moisture barrier and un derfloor heating pipes or cables from the thermal radiation...

Page 6: ...When installing a modular smoke flue safety clearances stipulated in the in stallation manual of the smoke flue shall be followed The minimum recommended diameter of a modular smoke flue is 120 mm The...

Page 7: ...ue is done from the above a Kota connective flue or Kota smoke flue must be used In case of connection from the above a Kota smoke flue tank for heating water or a Kota stone basket can be installed a...

Page 8: ...es Before using the stones they must be washed to eliminate any impurities Bigger stones are placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely b...

Page 9: ...from above reduces pollution and ensures cleaner burning The power of the sauna heater can be regulated by the ash drawer If the ash drawer is closed the power of the sauna heater is at its lowest and...

Page 10: ...n the stones of the sauna heater to dry the sauna room In the ignition phase the closing pan must be fully open Before you close the closing pan after heating check that there is no glowing coal in th...

Page 11: ...se installation and maintenance meet the requirements stipulated in the instructions The warranty period starts form the moment that the goods are delivered to the end user The supplier is not liable...

Page 12: ...t i e nominal space heating output Back Side Ceiling 150 mm 150 mm 1 250 mm Pass Pass NPD Pass Pass 0 07 Pass 70 12 Pa 16 kW 7 kg Pass Pass 387 C Narvi Oy 12 EN 15821 2010 Multi firing sauna stoves fi...

Reviews: