10
-
3. MAINTENANCE
3.1. General maintenance
-
Oil level container must be checked up every 500 hours of use.
In the frontal part of the container we can find the oil level cap. In case of lack of oil, please fill up the con-
tainer until the oil cap shows 3/4 parts full.
Picture 5
-
Replace hydraulic oil of the container every 2000 hours of work or every 3 years.
Type: CEPSA HIDRAULICO HM 68
Picture 5. Identification of the Components of the hydraulic container
WARNING
Stop the machine and press the emergency stop to carry out the oil change.
Pictures 6 and 7
Once the oil has been changed, start up the machine and press the pedal intermitently raising up the pres-
sure time gradually until the circuit is full. You
’
ll see the machine running its normal route.
-
Grease punches periodically according to the use received.
-
If t is daily and steadily used, grease it everyday.
-
If it is daily used but just on and off, then grease ut every week.
-
If the use is just sporadic, then grease it once a month.
Picture 6. Stop The Machine
Picture 7. Press the emergency stop