NARDI COMPRESSORI SUPER EXTREME Operating Manual Download Page 3

ENGLISH

 

Congratulations! You have just bought the best compressor in the market. 

Read  the  following  booklet  carefully  and  follow  these  instructions  before  you  start  using  the  compressor  so  you  can  become 

familiar with the machine in order to make full use of its potential without endangering your safety or damaging the appliance. The 

CE  marking  indicates  that  the  compressor  meets  European  Union  standards  EEC  Directives  2006/42/EC,  2009/105/EC, 

2004/108/EC, 2002/95/CE, 2002/96/EC, 93/68/EEC, EN292/2, EN 294, EN 60204-1. 

Safety precautions 

Strictly observe the following safety measures: 

1.

 

Move the compressor by suitable means to avoid exerting excessive effort to the upper and lower limbs.

 

 

2.

 

Sound pressure  is  below 80  dB (A), however in case of  prolonged use it is recommended the use of protectors  such as 

headphones. 

3.

 

Do not move the compressor while in operation as this may cause health risks for exposure to vibrations to your limbs 

(hand-arm). 

4.

 

If the machine is not working properly, please do not try any electrical or mechanical repairs of any kind. Contact your 

supplier immediately. 

5.

 

Do not use the compressor in environments that do not allow proper circulation of air. 

6.

 

Do not vent toward flames, heat sources, people and animals. 

7.

 

Please avoid, above all the use in very hot climates or during Summer, a prolonged exposure of the machine to the direct 

sun light, in order not to overheat plastic parts, the working temperature should be b5 and +50 ° C. 

8.

 

Keep away from the function of children and animals. 

9.

 

Do not use the compressor in humid or dusty environment. 

10.

 

Do not tamper with safety devices and regulation. 

Starting  the  machine. 

Make sure no damages due to carelessness or negligence occurred during transportation, before you start 

the  machine.  If  this  should  be  the  case,  notify  the  dealer  or  transportation  company  immediately.  After  having  checked  the 

equipment observe the following instructions: 

a.

 

Remove  the  electric  cable  and  insert  the  plug  in  a  current  collector  of  adequate  power.  Make  sure  if  fits  tightly  and  it 

ensures the connection of the poles of the plug to the grounding. Make sure the mesh voltage corresponds to the value 

indicated on the table of the fairing. 

b.

 

To help the electric motor start, make sure the air hose in not under pressure and the air outlet cock is open. 

c.

 

Start the electric motor by operating on the switch (ref. 2 fig. A). 

Use. 

The  compressor  is  equipped  with  two  air  flow  adjusters  (ref.  6  fig.  A)  which  enables  the  operator  to  control  the  working 

pressure.  Said  pressure  is  measured  with  the  manometers  (ref.  4-8  fig.  A).  The  regulator  adjusts  the  color 

BLACK

  maximum 

pressure up to 10 bar, the pressure regulator regulates the pressure 

RED

 0 to 30 Bar. 

CAUTION:

  Use  only  accessories  which  are  suitable  for  pressures  of  30  Bar.  Do  not  use  common  accessories,  without  first  having 

checked their actual working pressure, thus avoiding serious risks for the operator. 

Connect the chosen accessory to the air outlet cock (ref. 7-9 fig. A) and, keeping it closed, operate on the knob of the regulator (ref. 

6-10  fig.  A)  until  the  desired  working  pressure  is  reached.  After  this  operation  is  completed,  open  the  cock  until  the  needed  air 

capacity is reached. Keep in mind that, by alternately adjusting both the regulator and the cock, an optimal pressure air ratio can be 

obtained. 

Turning  the  machine  off.

 The compressor  is  equipped with an air pressure  switch (ref. 3 fig.  A)  which automatically controls the 

starting and turning off procedures of the compressor electric motor; nevertheless, to stop the compressor independently from the 

air pressure switch, use the general red switch (ref. 2 fig. A).

 

The discharge pressure of the pump unit takes place via the solenoid 

valve (fig. ref.11) at power off. 

IMPORTANT: Never stop the motor by unplugging the unit! Unplug the power cable ONLY after the compressor is switched off. 

Maintenance. 

Unscrew  the  filter  (ref.  1  fig.  A)  and  clean  it  periodically  using  an  air  jet  moving  from  the  center  to  the  outside. 

Because of the rapid expansion of the air inside the compressor tank, the humidity in the air condensates. It is therefore necessary 

to periodically discharge the condensate from the tank by unscrewing the drain plug (ref. 5 fig. A) and slightly tilting the tank. 

Important.

 The electric motor is protected by a thermic circuit breaker: the thermal protection switch device is activated when the 

motor overheats and causes sudden stop or intermittent operation of the compressor. 

In this case, make sure that: 

a.

 

The network voltage corresponds to the one indicate on the label.

 

b.

 

The maximum calibration pressure of the pressure switch is lower than or equal to the pressure indicated on the label.

 

c.

 

No strange noise or vibration is noticeable when the compressor is in operation.

 

Warranty.

    The  compressor  is  guaranteed  for  a  period  of  12  months  from  purchase  date  against  manufacturer  defect.  It  is 

important to keep the original purchase document (invoice or similar) to vouch for the validity of the warranty. It is furthermore 

necessary to use the compressor as indicated in this booklet and show it has not been tampered with. The warranty covers only the 

replacement of those parts which are faulty because of assembly or manufacturer defects. All transportation or operation fees are 

for account of  the client.

 

 

Recycling

: Please do not dispose of the compressor in the environment as waste. The compressor must be collected 

recycled or recovered as per the Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC.

 

Summary of Contents for SUPER EXTREME

Page 1: ...rating Manual Manuale d uso Mode d emploi Bedienungsanleitung Manual de instrucciones ________________________________________ SUPER EXTREME Mod Libretto ________________________________________ XTREM...

Page 2: ...RS OHNE L COMPRESOR DE AIRE SIN ACEITE 11 TECHNICAL DATA SPECIFICHE TECNICHE TECHNISCHE DATEN DONN ES TECHNIQUES DETALLE Air intake Aria aspirata Air aspir Luft Aire Max pressure Pressione massima Pre...

Page 3: ...pressure regulator regulates the pressure RED 0 to 30 Bar CAUTION Use only accessories which are suitable for pressures of 30 Bar Do not use common accessories without first having checked their actua...

Page 4: ...Bar il regolatore di pressione ROSSO regola la pressione 0 a 30 Bar ATTENZIONE Usare solamente accessori adatti a pressioni di 30 Bar Non usare accessori comuni senza prima aver verificato la reale p...

Page 5: ...bars La molette de r glage ROUGE permet d ajuster la pression maximale de 0 30 bars de pression ATTENTION Utilisez uniquement des accessoires qui conviennent pour des pressions de 30 bars Ne pas util...

Page 6: ...lliert werden kann Der Druckregler in SCHWARZ bietet dabei einen maximalen Druck von 10 bar und der Druckregler in ROT regelt den Druck von 0 bis 30 Bar ACHTUNG Verwenden Sie bei letzterem ausschlie l...

Page 7: ...a presi n m xima de hasta 10 bar el regulador de presi n ROJO regula la presi n de 0 a 30 bar PRECAUCI N Utilice nicamente accesorios que sean adecuados para presiones de 30 bar No utilice accesorios...

Page 8: ...ecting Rod Complete 1 Stage AT069 001 LAV01 Pipe Fitting L EX069 001 Cover fan Rear AT069 001 OGIVA Nut EX072 004 Metal inside cover fan EX011 001 Bearing for compressor monobloc EX072 006 3000 Cover...

Page 9: ...ipple AC004 006 Pressure Regulator 0 30 Bar AC017 052 Pipe fitting L AC005 002 Manometer 0 10 Bar AC017 130 Pipe fitting L AC005 008 Manometer 0 30 Bar AC019 060 Pipe fitting T AC006 006 Universal cou...

Page 10: ...2 Silencer AC005 002 Manometer 0 10 Bar AC015 001 Nipple VB006 021 Screw AC005 008 Manometer 0 30 Bar AC016 020 Nipple VB008 020 Screw AC006 006 Universal coupler 10 Bar with safety system AC016 029 N...