Accessories 4-1 

 

 

4 - Accessories

 

 
4.1 Introduction 
 
 

 
This section provides the information required for installing and using the 
accessories of the PMM RA-01 Active Rod Antenna. 
Information is included regarding initial inspection, power requirements, 
interconnections, work environment, assembly, cleaning, storage and 
shipment.

 

The following general information is applicable to all accessories. 

 

4.2 Preliminary  
        inspection 
 
 

 

Inspect the packaging for any damage. 
 

If the packaging or anti-shock material have been damaged, check 
that the contents are complete and that the meter has not suffered 
electric or mechanical damage. 
Check that all the Accessories are there against the checklist found 
with the apparatus. 
Inform the carrier and NARDA of any damage that has occurred. 

 
 

4.3 Work environment 

Unless otherwise specified, the work environment of the Accessories, must 
come within the following conditions: 

 

 Temperature 

  Humidity (without condensation) 

 

From -10°C to +60° C 
< 98% relative 
 

 

The Accessories must be stored in a clean and dry environment, free from 
dust, acids and humidity. 
The storage environment must come within the range of the following 
conditions: 

 

 Temperature 

  Humidity (without condensation) 

From -30°C to + 75° C 
< 98% relative 
 

4.4 Return for repair 

When the Accessories need to be returned to NARDA for repair, please 
complete the questionnaire appended to this User’s Manual, filling in all the 
data that will be useful for the service you have requested. 
For reducing the period of time required for the repairs, it is necessary to 
be as specific as possible in describing the problem. If the problem only 
occurs in certain circumstances, please describe in detail how it happens. 
If possible it is better to reuse the original packaging; making sure that the 
apparatus is wrapped in thick paper or plastic. 
Otherwise, use strong packaging by using a sufficient quantity of shock 
absorbent material around all sides of the meter to ensure that it is 
compact and does not move around inside the package.  
In particular, take every precaution to protect the front panels.  
Finish the package by sealing it up tightly. 
Apply a FRAGILE label to the package to encourage greater care in its 
handling. 
 
 

4.5 Cleaning 
 

 

Use a dry, clean and non-abrasive cloth for cleaning the instruments. 
 

Do not use solvents, acids, turpentine, acetone or other similar 
products for cleaning the devices in order to avoid damaging them.  

 

 

                                                      
Document RA01EN-71011 - 

 NARDA 2017 

Summary of Contents for PMM RA-01

Page 1: ...THE INSTRUMENT You can find the Serial Number in a side of the box Serial Number is in the form 0000X00000 The first four digits and the letter are the Serial Number prefix the last five digits are t...

Page 2: ...SYMBOLS You now own a high quality instrument that will give you many years of reliable service Nevertheless even this product will eventually become obsolete When that time comes please remember tha...

Page 3: ...3 1 4 2 Mounting Instructions Page 2 1 Introduction 2 1 2 2 Initial inspection 2 1 2 3 Environment 2 1 2 4 Return for service 2 1 2 5 Equipment cleaning 2 1 2 6 PMM RA 01 mounting instructions 2 2 3...

Page 4: ...M TR01 Wooden Tripod Adjustable joint Column strengthener Soft carrying case RA 01 parts and assembly Page 1 1 1 4 1 4 4 2 4 2 4 3 4 3 4 4 Tables Table 1 1 1 2 4 1 4 2 4 3 Technical Specification Main...

Page 5: ...In case of connection of the device to the power mains make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains Devic...

Page 6: ...sul Neva SV Italy sulla base delle seguenti norme europee armonizzate applicate con esito positivo based on the following harmonized European Standards successfully applied EMC Emissioni EMC Emission...

Page 7: ...o sul Neva SV Italy sulla base delle seguenti norme europee armonizzate applicate con esito positivo based on the following harmonized European Standards successfully applied EMC Emissioni EMC Emissio...

Page 8: ...VIII EC Conformity This page has been left blank intentionally...

Page 9: ...Active Rod Antenna 1 1 Documentation Enclosed with this manual are a service questionnaire to send back to NARDA in case an equipment service is needed an accessories checklist to verify all accessor...

Page 10: ...ng the actual antenna factors and performance characteristics of an antenna instead of typical data you can more accurately calculate the field strength in your tests Annual recalibration is recommend...

Page 11: ...d RA 01 MIL TOTAL w rod ext 9 kHz 30 MHz RA 01 150kHz 30 MHz RA 01 HV 50 BNC female Ni MH Rechargeable 7 2 V 720 mAh 24 hours 6 hours Threaded insert UNC 10 dB m nominal 10 C to 60 C 0 to 98 RH withou...

Page 12: ...rts Legend 1 Box Pre Amplifier and Adapting impedance 2 Counterpoise 3 Monopole antenna with the male thread 4 Monopole antenna RA 01 box front view Fig 1 3 PMM RA 01 front view Legend A ON OFF Switch...

Page 13: ...nna should be returned to NARDA for service please complete the service questionnaire enclosed with the Users Manual and attach it to the instrument To minimize the repair time be as specific as possi...

Page 14: ...ing Instructions 2 6 PMM RA 01 Mounting Instructions Remove two screws from the box as shown below Install the Counterpoise to the box with the side untouched on the top used the two screws removed pr...

Page 15: ...Mounting Instructions 2 3 Screw the monopole antenna with male thread to the box Screw a second monopole antenna to male thread To Install the RA 01 on the TR 01 optional accessory see chapter 4...

Page 16: ...2 4 Mounting Instructions This page has been left blank intentionally...

Page 17: ...ing and being sure to avoid ESD effects The static charge carried by test personnel can damage the FET 3 5 Principles of operation The most important assumption to be done concerns the length of the m...

Page 18: ...na factor is about 10dB If for example the output of the antenna is 44dB V and the antenna factor is 10dB at the radiated frequency the electric field magnitude is 44 10 54 dB V m corresponding to 0 0...

Page 19: ...ange of the following conditions Temperature Humidity without condensation From 30 C to 75 C 98 relative 4 4 Return for repair When the Accessories need to be returned to NARDA for repair please compl...

Page 20: ...PMM TR 01 Wooden tripod with extension Specifications Characteristics Performance Limits Legs Transportation width Minimum height Maximum height Weight Load capacity 3 legs x 3 sections extensible 76...

Page 21: ...mm 184 g 10 kg The Column strenghthner allows to mount the RA 01 on the PMM TR 01 Wooden tripod with extension Fig 4 3 Column strenghthner TABLE 4 3 Soft carrying case Specifications Dimensions 160 x...

Page 22: ...4 4 Accessories 4 6 2 RA 01 installation on TR 01A Wooden tripod Fig 4 5 RA 01 parts and assembly Legend 1 RA 01 2 Column strengthener 3 PMM TR01 Wooden Tripod...

Page 23: ...Accessories 4 5 Unscrew the pan head screw from Column strengthener without losing it completely Screw the Column strengthener on the RA 01 bottom be sure that it is well locking...

Page 24: ...ing it completely from the TR 01 Install the PMM TR 01 Wooden Tripod on the site Insert the Column strengthener fixed to RA 01 on the wooden extension and make sure it is fully inserted then screw the...

Page 25: ...would like to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would...

Page 26: ...Suggerimenti Commenti Note Suggestions Comments Note...

Reviews: