background image

Operation manual V3.2 for AcmeG series 

- 3 - 

Important Safety Instructions 

Please  read  this  operation  manual  carefully.  It  offers  very  important  safety 

instructions, installation and operation guide, and ensure your equipment with best 

performance and prolong the service life of your equipment. 

·

 

For the sake of your safety, please do not attempt to remove the components of 

the battery. The maintenance of the battery can only be  carried out by service 

engineers specially trained by the principal. 

·

 

Considering  the  potential  harm  of  the  lead  component  to  the  health  and 

environment, the battery can be replaced only by the service center authorized 

by the manufacturer. To replace the battery or maintenance equipment, please 

call the after-sales service hotline for information of the nearest service center. 

·

 

Please  check  the  local  regulations  on  the  correct  way  of  dealing  with  battery 

disposal or send the battery to the authorized service center for replacement. 

·

 

Battery  replacement  should  be  operated  or  supervised  by  engineers  who  are 

experienced and aware of the preventive measures on the potential harm of the 

battery. 

·

 

Warning - Do not smoke and refrain having fire near the battery. 

·

 

Warning - Do not use any organic solvent to clean the battery. 

·

 

Warning - Do not have fire near the battery or it may explode. 

·

 

Warning  -  Do  not  remove  the  components  of  the  battery  as  it  contains 

electrolyte that may cause injury to the human body. 

·

 

Warning  -  Battery  may  cause  short  circuit.  Please  remove  any  watches  and 

jewelry during replacement of the battery, and operate with tools with insulated 

materials. 

 

 

 

 

 

 

Warning 

Electricity 

danger 

Protecting your eye 

Watch 

Short-circuits 

With adults custody   

 

 

 

 

 

Read the 

manual 

Fire 

forbidden 

Circle use   

Do not put 

batteries into 

dustbin   

The product has past 

the UL Safe 

authentication 

 

Summary of Contents for ACMEG AG12V50F

Page 1: ...Polymer Gel Standby Battery Front Access Design OPERATION MANUAL Version 3 2 NARADA POWER SOURCE CO LTD Website www naradapower com...

Page 2: ...al Characteristics 7 1 Charge Performance Curve 7 2 Internal Resistance and Short Circuit Current 7 3 Discharge data with constant current constant power 9 Chapter Three Operation and Maintenance 15 1...

Page 3: ...ter Please check the local regulations on the correct way of dealing with battery disposal or send the battery to the authorized service center for replacement Battery replacement should be operated o...

Page 4: ...ion design with excellent heat dispersing capability Both positive and negative posts are along one side of the battery giving ease of monitoring and maintenance Flexible connectors that can fit accor...

Page 5: ...0 395 108 287 31 0 AG12V125F 12 125 558 125 270 46 0 AG12V150S 12 150 550 125 283 48 0 AG12V155F 12 155 558 125 270 52 5 AG12V170S 12 170 550 125 283 51 5 AG12V180 12 180 558 125 316 60 5 AG12V190 12...

Page 6: ...Operation manual V3 2 for AcmeG series 6 AG12V180 AG12V190 AG12V200 AG12V100S AG12V150S AG12V170S AG12V190S 558 21 99 316 12 45 125 4 93...

Page 7: ...C 2 Internal Resistance and Short Circuit Current The internal resistance of the battery is a dynamic nonlinear parameter that varies continuously with the temperature and discharge state The internal...

Page 8: ...ent A AG12V50F 8 94 1500 AG12V85F 6 52 1897 AG12V100F 6 36 1989 AG12V100S 5 52 2318 AG12V100A 6 59 1909 AG12V125F 5 76 2226 AG12V150S 5 19 2450 AG12V155F 4 30 2814 AG12V170S 4 65 2758 AG12V180 3 85 32...

Page 9: ...5 97 4 91 4 17 2 71 2 28 AG12V85F 5min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 12h 20h 24h 1 60V cell 305 6 164 2 99 9 72 2 58 4 33 5 24 3 19 1 16 1 13 8 10 6 8 75 7 40 4 64 3 87 1 67V cell 287 0 1...

Page 10: ...1 9 128 2 94 6 76 1 43 1 31 4 25 8 22 6 19 4 15 2 12 5 10 76 6 73 5 64 1 80V cell 314 2 188 3 122 5 90 7 74 1 42 8 31 2 25 7 22 1 19 1 15 1 12 4 10 67 6 66 5 63 1 83V cell 299 4 172 4 120 2 87 7 70 8...

Page 11: ...32 8 27 3 22 2 18 0 15 5 9 52 8 04 1 85V cell 337 7 240 2 170 9 131 7 113 6 66 0 48 2 39 0 32 3 27 0 21 9 17 9 15 4 9 52 7 99 AG12V100A 5min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 12h 20h 24h 1 6...

Page 12: ...9 286 4 178 9 134 4 109 3 63 2 46 2 36 6 30 8 26 6 20 6 16 9 14 24 9 15 7 64 1 67V cell 492 4 281 3 177 2 133 5 108 4 63 1 45 6 36 5 30 8 26 4 20 5 16 8 14 24 9 07 7 64 1 70V cell 489 8 278 0 177 2 13...

Page 13: ...534 6 322 1 229 4 169 5 137 5 82 5 58 9 49 4 42 7 36 9 29 3 24 2 20 47 13 60 11 34 1 85V cell 499 6 314 2 212 5 162 8 133 0 79 8 57 3 48 8 41 7 36 2 28 4 23 9 20 21 13 35 11 25 AG12V155F 5min 15min 3...

Page 14: ...8 38 8 33 4 19 7 17 2 AG12V100A 5min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 12h 20h 24h 1 60V cell 601 0 339 3 211 9 159 2 129 5 74 3 54 3 43 0 36 3 31 3 24 2 19 92 16 73 10 76 8 98 1 67V cell 578...

Page 15: ...h 2 2 Factors that influence the Actual Capacity Actual capacity is mainly related to the battery s construction manufacturing process and operational environment During operation the factors that inf...

Page 16: ...data such as capacity life and floating voltage are measured with temperature between 20 C 25 C as a standard The capacity of the battery will decrease with lower temperature as shown in Fig 3 1 belo...

Page 17: ...current will get larger and increase the grid eroding speed thus reducing the service life of the battery When the floating voltage is too low the battery will not be able to maintain its fully charg...

Page 18: ...k 5 2 45 14 7 10 2 425 14 55 15 2 40 14 4 20 2 375 14 25 25 2 35 13 95 30 2 325 14 25 35 2 30 14 10 40 2 275 13 65 Note If ambient temperature below 5 or above 40 temperature compensate is no longer g...

Page 19: ...mended as follows The batteries should first be charged on the constant current of 0 10C10A till the average voltage of the batteries increases to 14 1V then the batteries should be charged with const...

Page 20: ...by self discharge the batteries should be recharged as storage period shown in following table The equalization charge method should be adopted Storage temperature Max Storage period Above 30 3 months...

Page 21: ...e battery If there is more than one battery with voltage of less than 13 1V after temperature adjustment the batteries have to go through equalization charged If the problem persists after adopting th...

Page 22: ...ome cases 9 6V The battery will stop discharging when it reaches a certain voltage If the end voltage is too low it will be difficult to recharge the battery and decrease the charging efficiency thus...

Page 23: ...nnex 1 VRLA Battery Regular Maintenance Record Type Place Status Number of battery Total Voltage V Current A Temperature No Voltage V No Voltage V 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11...

Page 24: ...Operation manual V 3 2 for AcmeG series 24...