W415-1461 / C / 08.04.16

8  

3.0  INSTALLATION

NOTE:  Follow all National and local electrical codes. 

!

WARNING

RISK OF FIRE! THE POWER CORD MUST NOT BE PINCHED AGAINST A SHARP EDGE. SECURE CORD TO AVOID 

TRIPPING OR SNAGGING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY. DO NOT RUN 

CORD UNDER CARPETING. DO NOT COVER CORD WITH THROW RUGS, RUNNERS OR THE LIKE. ARRANGE CORD 

AWAY FROM TRAFFIC AREAS AND WHERE IT WILL NOT BE TRIPPED OVER.

RISK OF FIRE! TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKE OR EXHAUST IN ANY MANNER. DO NOT 

USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED.

RISK OF FIRE! DO NOT BLOW OR PLACE INSULATION AGAINST THE APPLIANCE.

THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES. 

USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC APPLIANCE COULD VOID THE 

WARRANTY AND/OR RESULT IN A SAFETY HAZARD.

IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT 

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER 

FLAMMABLE VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

THIS APPLIANCE IS HEAVY. IT IS HIGHLY RECOMMENDED THAT TWO PEOPLE INSTALL THIS APPLIANCE.

HEATER VENTS ON THE ELECTRIC APPLIANCE CANNOT, IN ANY WAY, BE COVERED AS IT MAY CREATE A FIRE 

HAZARD.

DO NOT RUN THE POWER CORD HORIZONTALLY, DIRECTLY BELOW THE APPLIANCE.

68.5A

Do not install the log set 

into a cavity smaller than 

that referenced in the 

table.

HEIGHT

 WIDTH

DEPTH

LOG SET

A

B

C

NEFI24H

15" 

(381mm)

24" 

(610mm)

14" 

(356mm)

NEFI27H

16" 

(406mm)

27 1/2" 

(698mm)

14" 

(356mm)

A

B

C

3.1  LOG SET INSTALLATION

The log set can be installed in any location. It is suggested to install the log set into an existing fireplace or a 

wood mantel for aesthetic purposes.

Select a suitable location that is not susceptible to moisture and is away from drapes, furniture and high 

traffic areas.

3.1.1  INSTALLING LOG SET INTO EXISTING FIREPLACE

MINIMUM FIREPLACE CAVITY SIZE

The log set insert must be installed in an opening with the minimum cavity sizes shown below:

NOTE: Seal all chimney drafts with non-combustible materials to prevent any chimney debris from 

falling onto the log set. Cap the top of the chimney flue to prevent rain from entering.

Plug the log set into an outlet which has a 15Amp, 120V rating. If it is necessary to hard wire the log set see 

"HARD WIRING INSTALLATION" section.

WARNING: Due to the high temperatures, do not use existing fireplace doors which close or seal off 

the log set. If installed behind any fireplace door, allow heat to be exhausted. If using existing screens, 

the screen must provide adequate airflow in front of the log set.

Summary of Contents for Woodland HEFI27H

Page 1: ...ntucky USA 41030 Phone 705 721 1212 Fax 705 720 9081 www napoleonfireplaces com hearth napoleonproducts com SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly...

Page 2: ...WIRING INSTALLATION 10 3 3 SECURING THE LOG SET 11 4 0 OPERATING INSTRUCTIONS 12 4 1 OPERATING CONTROL PANEL 12 4 2 OPERATING BY REMOTE CONTROL 13 4 3 REMOTE BATTERY INSTALLATION 13 5 0 FINISHING 14...

Page 3: ...int from carpeting bedding material etc The appliance area must be kept clear and free from combustible materials gasoline and other ammable vapors and liquids Under no circumstances should this appli...

Page 4: ...EN W415 1461 C 08 04 16 4 1 1 DIMENSIONS 14 356mm 24 610mm NEFI27H ILLUSTRATED 14 356mm NEFI24H ILLUSTRATED 27 686mm 151 2 393mm 14 356mm FRONT VIEW SIDE VIEW...

Page 5: ...ND OR RESULT IN A SAFETY HAZARD DO NOT OPEN RISK OF ELECTRIC SHOCK NO USER SERVICEABLE PARTS INSIDE DO NOT USE DAMAGED ELECTRICAL CORDS SERVICING SHOULD BE DONE ONLY WHILE THE APPLIANCE IS DISCONNECTE...

Page 6: ...250 F RATING CIFICATION BLACK LETTERING ON WHITE BACKGROUND MINIMUM FONT SIZE TO BE MINIMUM OF 8 5 PT 3 2mm OVERALL SIZE 6 x 3 AL NUMBERS TO BE ASCENDING FROM NEFI24 00601 E RATING PLATE NEFI24H SION...

Page 7: ...N AND MAINTENANCE TO PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION THE ELECTRIC APPLIANCE MUST NOT BE INSTALLED AGAINST VAPOR BARRIER OR EXPOSED INSULATION LOCALIZED OVERHEATING COULD OCCUR AND A F...

Page 8: ...ATER VENTS ON THE ELECTRIC APPLIANCE CANNOT IN ANY WAY BE COVERED AS IT MAY CREATE A FIRE HAZARD DO NOT RUN THE POWER CORD HORIZONTALLY DIRECTLY BELOW THE APPLIANCE 68 5A Do not install the log set in...

Page 9: ...t the log set down and into place see Figure 2 NTEL DO NOT SLIDE LOGSET NE GLISSEZ PAS L APPAREIL MANTEL STEP 1 LIFT STEP 2 INSERT STEP 3 SET APPLIANCE MANTEL DO NOT SLIDE LOGSET NE GLISSEZ PAS L APPA...

Page 10: ...RING CONNECTION If it is necessary to hard wire a qualified electrician must remove the cord connection and wire directly to the household wiring The wire and power supply breaker must be rated for 12...

Page 11: ...rmance NOTE To achieve flame effect the log set should be set 1 away from the rear wall B Secure in place using 2 screws not supplied EN W415 1461 C 08 04 16 11 3 3 SECURING THE LOG SET NOTE It is rec...

Page 12: ...ings 61 F 64 F 70 F 75 F 81 F 85 F and OFF Default setting is de select Temperature Control F C SWITCH Hold 5 seconds To change temperature format Fahrenheit or Celsius Press and hold the Flame button...

Page 13: ...D To activate the heater and blower press the heater button the blower will turn on Press the heater button again to set desired low or high heat temperature press the heater button again to turn off...

Page 14: ...e pin Ensure the log is secure onto the pin as shown Place log 2 onto the pin Ensure the log is secure onto the pin as shown Place the logs shown on the location dimples on the burner platform Place t...

Page 15: ...onto the pin Ensure the log is secure onto the pin as shown Place log 3 onto the pin Ensure the log is secure onto the pin as shown NEFI27H 2 NEFI24H NEFI27H 3 PIN 5 3 EMBER BED PLACEMENT Place the em...

Page 16: ...f the ember bed as indicated on the diagram below NOTE Do not block air intake opening and outlet with charcoal embers CHARCOAL EMBERS OUTLET OPENING AIR INTAKE OPENING BRAISES DE CHARBON L OUVERTURE...

Page 17: ...MAIN PCB BOARD L N G WIRE NUT CONNECTEUR DE FILS WIRE NUT CONNECTEUR DE FILS WIRE NUT CONNECTEUR DE FILS HEATER 700W2 CHAUFFERETTE 700W2 HEATER 700W1 CHAUFFERETTE 700W1 THERMAL CUT OFF COUPURE THERMIQ...

Page 18: ...UBJECT TO CHANGE WITHOUT NOTICE PARTS IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN 2 TO 5 BUSINESS DAYS FOR MOST DELIVERY DESTINATIONS PARTS NOT IDENTIFIED AS STOCKED WILL BE DELIVERED WITHIN A 2 TO...

Page 19: ...5 0604 W135 0601 W135 0603 W135 0600 W135 0602 W135 0610 W550 0013 G405 0011 G190 0005 DESCRIPTION PART NO REF 1 W135 0605 2 3 4 5 6 7 8 9 10 11 12 13 W405 0023 W405 0025 G405 0012 W435 0059 W005 0019...

Page 20: ...EFLECTOR TOR NEFI27H BUSHING CONTROL PANEL NEFI27H CONTROL PANEL BOARD TEMPERATURE SENSOR BLOWER HEATER ASSEMBLY SPACER 4 PCS 14 15 16 17 18 19 20 21 22 23 24 25 26 G190 0005 G660 0004 W750 0359 W010...

Page 21: ...h has tripped Unplug power or turn off the circuit breaker allow appliance to cool for 15 minutes to reset the thermal switch then plug in or turn it on Appliance will not come on when switch is flipp...

Page 22: ...Any damages to appliance brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The...

Page 23: ...EN W415 1461 C 08 04 16 23 10 0 NOTES 44 1...

Page 24: ...laces Outdoor Fireplaces Gas Grills Fireplaces Heating Cooling call 705 721 1212 Grills call 705 726 4278 napoleonproducts com 24 Napoleon Road Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie O...

Reviews: