background image

24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8 

 

Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com

Framing & Clearances

vECTOR

TM 

 45 DIRECT vENT GAS FIREPLACE

Minimum Fireplace Clearances

Framing Dimension

s

Appliance Location

Wall Penetration

Minimum vertical vent Rise

TOP OF 

FIREPLACE

OPENING

SHELF

COMBUSTIBLE

0” (0mm) IF NON-

COMBUSTIBLE 

 FINISHING IS USED

 SUCH AS BRICK AND

 STONE

NON-COMBUSTIBLE

NON-COMBUSTIBLE 

MATERIAL

VENT HEAT SHIELD

1" 25mm

2" 51mm

2" 51mm

1" 25mm

6" 152mm

MIN

45 13/16"

1164mm

                    MIN PLUS

                   RISE*

56 "

1422mm

                    MINIMUM 

                    ENCLOSURE

                   HEIGHT

30 11/16"

780mm

                  MIN

18 3/16"

462mm

                 

12 1/2"

317mm

                 

14"

356mm

                 

25 5/16"

643mm

              MIN

Product information provided is not complete and is subject to 
change without notice.  Please consult the installation manual 
for the most up to date installation information.

05/2015

DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE 

FOR THE VENT IN THIS 14” (356mm) WIDE AREA CENTERED ALONG THE FRONT OF THE

FIREPLACE. NO COMBUSTIBLES ARE ALLOWED. FIREPLACE SHOULD BE IN ITS FINAL LOCATION 

BEFORE FRAMING.

!

WARNING

46 3/4"

1187mm

         

41 1/4"

1048mm

56"

1422mm

                  MINIMUM FROM BASE

                OF APPLIANCE

14" 356mm    MIN

20 1/8"

511mm   *

INSIDE

CHASE

OUTSIDE 

CHASE

73 1/2"

1867mm

                  MIN

BACK WALL OF CHASE / ENCLOSURE 

(INCLUDING ANY FINISHING MATERIAL)

46 3/4" 1187mm

         

52"

1320mm

20 1/8"

511mm

20 1/8"

511mm

46 3/4" 1187mm

         

46 3/4" 1187mm

         

2" 51mm

         

Combustible Mantel Clearances

Reviews: