2

SAFETY PRECAUTIONS

WARNING

      Read the follow SAFETY PRECAUTIONS carefully before installation.
      Electrical work must be installed by a licensed electrician. Be sure to use the correct rating 
      

and  main circuit for the model to be installed.

      Incorrect installation due to ignoring of the instruction will cause harm or damage. 

          

The seriousness is classified by the following indications.

of the power plug 

This symbol indicates the possibility of death or serious injury.

The items to be followed are classified by the symbols:

Symbol with background white denotes item that is PROHIBITED from doing.

CAUTION

This symbol indicates the possibility of injury or damage to property.

WARNING

1)  Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water
     leakage, electrical shock fire.
2)  Install according to this installation instructions strictly. If installation is defective, it will cause water
     leakage, electrical shock fire.

3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall, 
     water  leakage, electrical shock fire.

4)  Install at a strong and firm location which is able to withstand the set s weight. If the strength is not enough
     or installation is not properly done, the set will drop and cause injury.

,

5)  For electrical work, follow the local national wiring standard, regulation and this installation instructions. An 
     independent circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found
     in electrical work, it will cause electrical shock fire.

6)  Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on
     the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.

7)  Wiring routing must be properly arranged so that control board cover is fixed properly. If control board cover 
     is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical shock.

8)  When carrying out piping connection, take care not to let air substances other than the specified 
     refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure 
     in the refrigeration cycle, explosion and injury.

9)  Do not modify the length of the power supply cord or use of extension cord, and do not share the 
     single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.

CAUTION

1)  This equipment must be earthed and installed with earth leakage current breaker. It may cause electrical
     shock if grounding is not perfect.

2)  Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and 
     accumulates at surrounding of the unit, it may cause fire.

3)  Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water 
      may enter the room and damage the furniture.

Summary of Contents for Room Air Conditioner

Page 1: ......

Page 2: ...pose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least...

Page 3: ...not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc Do not disassemble or modify unit WARNING Use the correctly rated breaker or fuse There is risk of fire o...

Page 4: ...timer def Auto indicator This indicator illuminates when the air conditioner is in AUTO operation Timer indicator This indicator illuminates when TIMER is set ON OFF Defrost Indicator For cooling hea...

Page 5: ...wer initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation CAUTION Manul operation can be used temporarily in case the remote controller is disable or maint...

Page 6: ...oling heating cooling heating models only or fan only operation depending on what temperature you have selected and the room temperature The air conditioner will control room temperature automatically...

Page 7: ...unit This is causedby the indoor unit giving offsmells permeated from building material from furniture or smoke 6 The airconditioner turns to FAN only mode from COOLor HEAT For cooling and heating mod...

Page 8: ...ilure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operati...

Page 9: ...s are excluded NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Any damages to the appliance due to water...

Page 10: ......

Page 11: ...on 3 5 After setting the TIMER there will be a one half second delay before the remote controller transmits the signal to the Air Conditioner Then after approximately another 2 seconds the signal h di...

Page 12: ...utton is pressed the fan speed mode is shifted 8 TIMER ON Button Press this button to initiate the auto on time sequence Each press will increase the auto timed setting in 30 minutes increments When t...

Page 13: ...window except the Auto fan speed 7 Operating the Remote Controller The Remote Controller uses two alkaline dry batteries LR03X2 1 To install the batteries slide the back cover of the battery compartme...

Page 14: ...ws TIMER ON the last set time for the starting operation and the signal h will be shown on the DIGITAL DISPLAY area You are now ready to reset the time to START the operation 1 2 Push the TIMER ON but...

Page 15: ......

Page 16: ...use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the...

Page 17: ...ring standard regulation and this installation instructions An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it wil...

Page 18: ...by arrows from wall or other obstacles Do not place animals and plants in the path of the air inlet or outlet Take the air conditioner weight into account and select a place where noise vibration and...

Page 19: ...m abo ve 30cm above Air Filter Air Filter Air Outlet 30cm above Wrapping tape B 200cm above Additional drain pipe Accessories Parts you must purchase Consult the dealer about the pipe size 6 35 9 53 1...

Page 20: ...mensions are in mm unless otherwise stated 1 Determine hole positions according to the diagramdetailed in Fig 5 Drill one 1 hole 65mm slanting slightly to outdoor side 2 Always use wall hole conduit w...

Page 21: ...the indoor unit with a cushioning material between the indoor unit and the wall Get it out after finish piping 4 Push the lower part of the indoor unit up on the wall then move the indoor unit from s...

Page 22: ...hose sloped downward to drain out the condensed water smoothly CAUTION Install the outdoor unit on a rigid base to prevent increasing noise level and vibration Determine the air outlet direction where...

Page 23: ...r tube pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing Pipe Reamer Point down Fig 16 Fig 17 Outdoor unit dimension mm WxHxD A mm B mm 530 290 484 600...

Page 24: ...air conditioner and explain to the client until the problem is solved 2 Power voltage should be in the range of 90 110 of rated voltage 3 The creepage protector and main power switch with a 1 5 times...

Page 25: ...osening the screw as shown in Fig 22 4 Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s respectively 5 Wrap those cables not connected with terminals with i...

Page 26: ...onnecting means must be provided and shall be located within sight from and readily accessible from the air conditioner Connecting cable with conduit shall go through the hole of the conduit panel Not...

Page 27: ...the fixed wiring and have an air gap contact separation of at least 3mm in each active phase conductors CAUTION CAUTION CAUTION CAUTION Air and moisture in the refrigerant system have undesirable eff...

Page 28: ...ully open the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose theflare nut of the Lo valve on the gas pipe side and check that the air is...

Page 29: ...If bubbles come out the pipes have leakage 2 Leak detector Use the leak detector to check for leakage Test running Safety and leakage check 14 TEST RUNNING Manual control button AUTO COOL Perform tes...