Napoleon ROGUE 365-1 Manual Download Page 8

8  

www.napoleon.com

N415-0574-AU REV A JUN 08.22

Gas Hook-Up Instructions

WARNING!

 A fire will result if the gas supply hose makes contact with the underside of the grill or 

drip pan

Cylinder Installation:

 

Check that the cylinder valve is closed by turning the knob clockwise. Check that 

the grill’s burner knobs are in the off position. Open cabinet doors. Set cylinder into hole in bottom 

shelf. 

Place the cylinder so that the valve faces toward the front of the grill. Other cylinders may be 

acceptable provided they fit properly into the tank retaining ring.

Cylinder Connection LCC27

:

 

Do not attempt to use a cylinder, which is not equipped with a LCC27 type 

connection. Do not use an adaptor at the cylinder connection. 

Ensure the gas regulator hose is kink free. 

Remove the cap or plug from the cylinder fuel valve. Insert the regulator onto the fuel valve. Hand tighten 

clockwise. Do not use tools. Leak test all joints prior to using the grill.

 A leak test must be performed 

annually and each time a cylinder is hooked up or if a part of the gas system is replaced. 

This gas grill is certified for outdoor use and should be installed in conformity with AS/NZS 5601 and local 

codes.  Check gas type and specifications located on the rating plate located on the back panel of the grill.

Universal Liquefied Petroleum Gas 

Cylinder Specifications

WARNING!

 

If these instructions are not followed exactly, a fire causing death or serious injury may 

occur.

WARNING!

 

Do not store a spare ULPG cylinder on the shelf beneath the barbecue.

This gas grill has been designed for use with an approved 9 kg size Universal Liquefied Petroleum Gas 

cylinder (not supplied).  The Universal Liquefied Petroleum Gas cylinder must be equipped with an LCC27 

tank valve connection. Do not use an adaptor at the cylinder connection. A dented or rusty cylinder may 

be hazardous and should be checked by your Universal Liquefied Petroleum Gas supplier. Never use a 

cylinder with a damaged valve. The cylinder supply system must be arranged for vapor withdrawal and the 

cylinder shall include a dust cap to protect the cylinder valve. The cylinder shall incorporate a listed OPD 

(overfill protection device).  Do not store a spare Universal Liquefied Petroleum Gas cylinder under or near 

this appliance. Never fill the cylinder beyond 80 percent full.  

!

!

Summary of Contents for ROGUE 365-1

Page 1: ...ll owner for future reference Adults and especially children should be alerted to the hazards of high surface temperatures Young children should be supervised near the gas grill Wolf Steel Ltd 214 Bay...

Page 2: ...ensed authorized service technician or contractor in accordance with the installation instructions included with the product and all local and national building and fire codes has been properly mainta...

Page 3: ...not be stored in a building garage or other enclosed area Natural gas units must be disconnected from the supply when being stored indoors Do not use or store flammable materials in or near this appli...

Page 4: ...Within a partial enclosure that includes an overhead cover and no more than two sidewalls These sidewalls may be parallel as in a breezeway or at right angles to each other Within a partial enclosure...

Page 5: ...FOLDED 48 122 cm 63 160 cm LID OPEN 36 3 4 94 cm 27 1 4 69 cm OVERALL DEPTH 35 1 2 91 cm 12 1 2 31 cm R365 GRILL GRILL SIZE 365 SQ IN 2350 cm 2 WARMING RACK SIZE 95 SQ IN 612 cm 2 ALL DIMENSIONS ARE...

Page 6: ...1 2 91 cm 48 122 cm 63 160 cm LID OPEN 36 3 4 94 cm 27 1 4 69 cm OVERALL DEPTH R425 GRILL GRILL SIZE 18 X 23 3 4 425 SQ IN 46cm X 59 5cm 2742cm 2 WARMING RACK SIZE 4 3 4 X 23 1 4 110 SQ IN 12cm X 59cm...

Page 7: ...med by a licensed gas fitter in accordance with AS NZS 5601 and all connections must be leak tested before operating the grill This natural gas grill is supplied with a 3000 mm supply hose with an ins...

Page 8: ...replaced This gas grill is certified for outdoor use and should be installed in conformity with AS NZS 5601 and local codes Check gas type and specifications located on the rating plate located on th...

Page 9: ...olution of liquid soap and water onto all joints and connections of the regulator hose manifolds and valves Bubbles will indicate a gas leak Either tighten the loose joint or have the part replaced wi...

Page 10: ...ition If the pilot lights continue to push down on the control knob until the burner lights and then release 3 If the pilot does not ignite then immediately turn the control knob back to the off posit...

Page 11: ...a normal temporary condition caused by the burn in of internal paints and lubricants used in the manufacturing process and does not occur again Simply run the main burners on high for approximately o...

Page 12: ...are best cleaned with a brass wire brush during the pre heating period Steel wool can be used for stubborn stains It is normal that stainless grids if equipped will discolor permanently from regular u...

Page 13: ...a golden or brown hue This discoloration is normal and does not affect the performance of the grill Porcelain enamel components must be handled with additional care The baked on enamel finish is glass...

Page 14: ...clean if the burner is removed from the grill but it can also be done with the burner installed Do not flex the drill bit when drilling the ports as this will cause the drill bit to break This drill...

Page 15: ...r to cleaning instructions Burners burn with yellow flame accompanied by the smell of gas Possible spider web or other debris or improper air shutter adjustment Thoroughly clean burner by removing See...

Page 16: ...cleaning instructions Burner output on high setting is too low Rumbling noise and fluttering blue flame at burner surface Lack of gas Supply hose is pinched Dirty or clogged orifice Spider webs or oth...

Page 17: ...ollowing information is required 1 Model and serial number of the unit 2 Part number and description 3 A concise description of the problem broken is not sufficient 4 Proof of purchase photocopy of th...

Page 18: ...th a protective plastic coating that must be removed prior to using the grill The protective coating has been removed from some of the parts during the manufacturing process and may have left behind a...

Page 19: ...eon com N415 0574 AU REV A Jun 08 22 WARNING FIRE HAZARD WARNING Do not route hose underneath drip pan WARNING Ensure the hose does not contact any high temperature surfaces or it may melt and leak ca...

Page 20: ...erviced Do not smoke while performing this test and remove all sources of ignition See Leak Testing Diagram for areas to check Turn all burner controls to the off position Turn gas supply valve on Bru...

Page 21: ...lf B x x 13 N475 0442 GY1SG rear cart enclosure panel x N475 0363 GY1SG rear cart enclosure panel x 14 N080 0378 GY1SG bracket pivot x x 15 N475 0356 GY1SG left right cart enclosure panel x x 16 N160...

Page 22: ...hting rod x x 38 N570 0118 1 4 20 x 3 8 screw x x 39 N120 0037 cap hub wheel x x 40 N745 0009 wheel x x 41 N015 0012 axle x x 42 N450 0023 nut plastic cap x x 43 N735 0027 washer 1 2 x x 44 N585 0137...

Page 23: ...napoleon com N415 0574 AU REV A Jun 08 22 41 38 5 13 40 38 19 42 20 38 18 38 44 45 38 11 17 16 8 9 38 7 39 6 34 32 14 29 29 28 28 30 30 31 31 33 33 1 1 36 27 32 3 4 22 23 12 15 37 10 26 25 24 43 35 4...

Page 24: ...Napoleon products are protected by one or more U S and Canadian and or foreign patents or patents pending N415 0574 AU...

Reviews: