www.napoleongrills.com
58
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, dam-
age to property, serious bodily injury, or death.
Leak testing
:
This must be done before initial use, annually, and whenever any gas components are re
-
placed or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
Summary of Contents for Prestige PRO 500
Page 4: ...www napoleongrills com 4 EN DIMENSIONS...
Page 24: ...www napoleongrills com 24 FR DIMENSIONS...
Page 46: ...www napoleongrills com 46 Propane Only Propane Seulement 3 8 10mm 2 x N570 0086 14 x 1 2...
Page 47: ...www napoleongrills com 47 Disposable grease tray R cipient graisse jetable...
Page 48: ...www napoleongrills com 48 2 x N430 0002 3 8 10mm 2 x N570 0086 14 x 1 2...
Page 54: ...www napoleongrills com 54 N520 0035 N305 0085...
Page 63: ...www napoleongrills com 63 PARTS DIAGRAM LISTE DES PI CES PRO500RB...
Page 68: ...N415 0248...