6
www.napoleongrills.com
Cylinder Connection
: Ensure the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand tighten clockwise. Do not use
tools. Leak test all joints prior to using the grill. A leak test must be performed annually and each time a cylinder
is hooked up or if a part of the gas system is replaced.
If this grill is to be connected directly to a house propane gas supply line, follow the instructions for the natural
gas hook-up. Optional side burners must also follow the natural gas hook-up instructions.
Note: The propane tank heat shield is not required when the grill is connected to a fixed fuel supply, as its sole
function is to shield the propane tank normally used with the grill. Ensure that the supply pressure is 11 inches
water column.
Natural Gas Hook-Up
: These connections must be made by a licensed gas fitter. This natural gas grill is supplied
with a gas supply hose (complete with a quick disconnect) designed for natural gas and certified for outdoor
use. The gas grill is designed to operate at an inlet pressure of 7 inches water column. Piping and valves
upstream of the quick disconnect are not supplied. The installation must comply with CAN B149.1 Natural Gas
and Propane installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
The gas supply pipe must be sufficiently sized to supply the BTU/h specified on the rating plate, based on the
length of the piping run.
The quick disconnect must not be installed in an upward direction and a readily accessible manual shut-off
valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The flared end of the
hose must be connected to the fitting on the end of the manifold tube or flex tube (if applicable) as illustrated
in the Natural Gas Hose Attachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe
dope.) Leak test all joints prior to using the gas grill.
WARNING!
• The installation must be performed by a licensed gas fitter, and all connections must be leak tested before
operating the grill.
• Do not route hose underneath the drip pan.
• Do not route hose between bottom shelf space and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on
any hose connection.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a fire.
• Leak test all the connections using a soap and water solution as per the leak testing instructions found in
the manual.
• The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 0.5 psi (3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).
Summary of Contents for PRESTIGE 500
Page 4: ...4 www napoleongrills com DIMENSIONS ...
Page 18: ...18 www napoleongrills com ...
Page 22: ...22 www napoleongrills com DIMENSIONS ...
Page 43: ...43 www napoleongrills com 10 Disposable grease tray Récipient à graisse jetable ...
Page 44: ...44 www napoleongrills com 11 2 x N570 0086 14 x 1 2 3 8 10mm 2 x N430 0002 ...
Page 50: ...50 www napoleongrills com 16 N520 0034 N305 0083 500RSIB N305 0084 ...
Page 59: ...59 www napoleongrills com P500 P500RB PARTS DIAGRAM DIAGRAMME DE PIÈCES ...
Page 63: ...63 www napoleongrills com P500RSIB PARTS DIAGRAM DIAGRAMME DE PIÈCES ...
Page 66: ...66 www napoleongrills com NOTES ...
Page 67: ...67 www napoleongrills com NOTES ...
Page 68: ...N415 0247 ...