EN
W415-2366 / A / 10.07.19
19
venting installation
3.1 horizontal
installation
A.
Level and affi x the mounting template to the wall at
the desired location and height. The centre of the
vent pipe must be located between wall studs.
B.
Using the template, mark the holes for the vent, gas
and electrical outlets, and the mounting screws (see
“minimum clearances to combustibles section”).
C.
Remove the mounting template from the wall and
cut the holes as marked.
D.
Remove the 4 screws that secure the wall mounting
plate to the appliance.
E.
If fl exible venting is to be used, remove the rigid
fi restop spacer.
F.
The shield and defl ector have been designed
to accommodate a maximum wall depth of 12"
(30.5cm). Determine the depth of the wall and cut
the shield and defl ector accordingly. The shield must
extend the full depth of the combustible wall.
G.
Screw the shield together using the screws
provided.
H.
Secure the ring to the fi restop plate on the back of
the mounting plate using the 4 screws provided.
I.
Bend the 6 tabs on the defl ector as shown.
J.
Slide the shield onto the ring and align the
holes. Using 6 of the screws provided,
secure the shield to the ring.
K.
Attach
the
defl ector above
the shield
assembly using
the 5 screws
provided.
L.
Apply a bead of
caulking (not supplied) to the fl ange. Insert
the shield assembly into the wall, level
the mounting plate, and secure it using 4
fasteners. The fasteners must be mounted to the wall studs.
DETERMINE
THE
CORRECT
HEIGHT
FINISH
MATERIAL
RING
SHIE
LD
DEFLECTOR
ELECTRICAL
OUTLET
GAS
OUTLET
RIGID
FIRESTOP
SPACER
VENT
FLANGE
CAULKING
BACK OF WALL
MOUNTING PLATE
BACK OF WALL
MOUNTING PLATE
FIRESTOP
PLATE
There are 2 sets of 4 mounting screws. Choose
the appropriate set for either 16” (40.6cm) or 24”
(61cm) studs.
note: