W415-1802 / D / 10.24.19
EN
34
maintenance
Your appliance comes equipped with our “Night Light™”. The light has been pre-wired and is controlled from the
remote control.
If the lamp or lens needs to be replaced, follow the instruc-
tions below.
A.
Unplug the appliance (plug located on right side of
appliance).
B.
Remove the 2 screws holding the light shield in
place.
C.
Remove the 4 screws that secure the lens frame
(Fig. 6-1)
. This frame retains the glass lens. The
lamp can now be accessed.
GASKET
LENS
FRAME
COLOURED SIDE UP
8.6
night light™ replacement (GDIG3 / GDIX3)
note:
Do not handle the lamp (bulb) with bare fi ngers.
Protect them with a clean, dry cloth.
Bottom of Appliance
Fig. 6-1
GDIG3 Illustrated
The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as lamp
and lens are special "high temperature" products. When re-installing, ensure integrity of
gasket seal.
THE FIREBOX MUST BE SEALED.
Over-tightening the screws could break the lens. “Light Leakage” from the upper area
may be observed. The holes in the lamp housing are necessary for ventilation and must
not be covered.
8.7
restricting vertical vents
Your appliance comes with restrictor plate fully closed. If carboning becomes an issue, adjust the restrictor plate
by loosening the four screws and pulling the plate forwards or backwards
(Fig. 6-2)
. Re-tighten the screws.
Screws
Restrictor Plate
Fig. 6-2