NOTES:
①
.
Based upon W/nominal tonnage, dry coil and filter should be installed.
②
.
Use 0.96 as approximate SCFM correction factor for wet coil.
2.6 Dip switch configuration
Set the indoor fan speed through the eight dip switches of the indoor main control
board. The higher level, the higher speed of the indoor unit fan. Operation Instruction is
below:
Dip switch settings must be completed before power on the unit.
After the unit is shut down or stopped at the temperature point, the indoor unit will
delay for a few minutes and then shut down. The refrigeration can realize the drying
function, relieve the mold of the air duct, and the heating can blow the waste heat and
relieve the heat accumulation in the air duct.
During installation and debugging, pay attention to check whether the temperature
controller has set the fan delay and shutdown time. If the temperature controller has
been set, the actual delay and shutdown time of the fan is equal to the temperature
controller setting time plus the fan delay time of the indoor unit.
Model
Level
Heat (SA2)
Cool (SA1)
NPFX24A
Level 1
1
0 0 0 0 0 0 0
Level 2
1
0 0 1 0 0 0 0
Level 3
1
0 1 0 0 0 0 0
Level 4-Default
1
0 1 1 0 0 0 0
Level 5
1
1 0 0 0 0 0 0
Level 6
1
1 0 1 0 0 0 0
Level 7
1
1 1 0 0 0 0 0
Level 8
1
1 1 1 0 0 0 0
NPFX24A36A
Level 1
0
0 0 0 0 0 0 0
Level 2
0
0 0 1 0 0 0 0
Level 3
0
0 1 0 0 0 0 0
Level 4-Default
0
0 1 1 0 0 0 0
Level 5
0 1 0 0 0 0 0 0
Level 6
0
1 0 1 0 0 0 0
Level 7
0
1 1 0 0 0 0 0
Level 8
0
1 1 1 0 0 0 0
6
Summary of Contents for NPFX24A
Page 18: ...Air Handlers 13...
Page 19: ...Air Handlers 14...
Page 21: ...Air Handlers 16...
Page 25: ...Air Handlers 20...
Page 26: ...Air Handlers 21...
Page 27: ...Air Handlers 22...
Page 28: ...Air Handlers 23...
Page 29: ...Air Handlers 24...
Page 41: ......
Page 42: ......
Page 43: ......