NOTE: Leave enough
wire so that the log
set can be removed
from the enclosure
without disconnecting
the power supply.
A.
Remove the securing screw from the electrical cover plate, located on the rear of the log set.
B.
Add an electrical box connector and feed the supply wires through the 7/8" (22mm) hole.
C.
Separate the black, white and green wires that have the wire nuts on them.
D.
Remove the wire nuts and secure the black wire (power L1) to the black (power L1) lead of the
power supply. Connect the white wire from the unit to the white (neutral) wire from the power
supply. Connect the green wire to the ground wire.
E.
Resecure the cover plate.
BLACK
WHITE
BLACK
WHITE
4
6
1
1
-
:
1
0
8
&
3
+
6
/
$
5
*
0
/
'
*
3
&
1
-
"
$
&
GREEN
GREEN
(L1)
(N)
(G)
WIRE NUT
EN
W415-1461 / 06.25.15
10
GREEN
BLACK
WHITE
HARD WIRING CONNECTION
If it is necessary to hard wire, a qualifi ed electrician must remove the cord connection, and wire directly to the
household wiring. The wire and power supply breaker must be rated for 120V and a minimum of 15 Amps.
This log set must be electrically connected and grounded in accordance with local codes, if hard wired. In the
absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current
ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
!
WARNING
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
GREEN
BLACK
WHITE
NOTE: There are 3 wires from the fi replace junction; white (neutral), black (power L1) and green
(ground) that connect to 120V power supply (breaker panel), see below.
White, Green and
Black wires:
Connect to 120V
power supply.
3.2 HARD WIRING INSTALLATION
NOTE: It is recommended to
secure the log set after hard
wiring, refer to "SECURING
THE LOG SET" section.