A -
control knob
B -
thermostat control
C -
oil level regulator
D -
safety lever
E -
filter
F -
main float
G -
safety float
H -
filter cavity
A
B
E
H
G
F
C
D
FIGURE 13
MAINTENANCE
WEEKLY - DESCALE
Push and pull the de-scaling lever in and out as well
as turning slightly at the same time completely two or
three times.
Push in for normal burner operations or
before relighting.
EVERY 3 TO 4 MONTHS - CLEAN BURNER
Remove all three catalyser components.
FIGURE 10.
Remove any carbon residue and remaining oil from the burner
using a slightly damp cloth. Buff dry before reinstalling.
YEARLY - CLEAN CARBURETOR FILTER
1.
Set the control knob to
0
.
2.
Turn off oil supply at the valve or the tank valve.
3.
Raise the safety lever (D).
4.
Place a container under the carburetor to contain any spillage. Remove
the filter plug held on with two screws.
5.
Pull out the filter (E) and clean in oil
using a soft brush
.
Never use a wire
brush.
6.
Replace filter and plug.
Clean all enamelled stove panels and the outside of the glass using a slightly
dampened cloth.
Never clean when the stove is hot
CHIMNEY INSPECTION AND MAINTENANCE
The chimney and the chimney connector must be inspected at least once every 3 months during the heating
season to ascertain whether there has been a buildup of soot in the system. If a soot buildup has occurred, it
should be removed to reduce the risk of chimney fires. The chimney is to be swept at least once a year. It is also
recommended that prior to every heating season the entire system be professionally inspected, cleaned and
repaired where necessary.
Summary of Contents for Model OS10