Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing
:
This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See
Leak Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve
on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a
certified gas installer.
If the leak cannot be stopped,
immediately shut off the gas supply
, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
Summary of Contents for LE485RB
Page 32: ...www napoleongrills com 32 4 x N570 0080 14 x 1 2 3 8 10mm...
Page 41: ...www napoleongrills com 41 2 x N160 0022 2 x N105 0011 2 3 1...
Page 42: ...www napoleongrills com 42...
Page 43: ...www napoleongrills com 43 Fett Auffangbeh lter Einweg disposable grease tray...
Page 66: ...www napoleongrills com 66 ELEKTRISCHER SCHALTPLAN NUR F R MODELLE MIT INTEGRIERTER BELEUCHTUNG...
Page 67: ...www napoleongrills com 67 Notes...
Page 68: ...N415 0220CE GB DE...