When the appliance is installed at elevations above 4,500ft (1371m), and in the absence of specifi c
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion / contraction noises during heating up
and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation
in a mobile home that is permanently positioned on its site and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
2.5 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
SERIAL NUMBER/NO. DE SERIE:
IR3G/CIR3G
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE THAT WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
AVERTISSEMENT:
N'A JOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET
APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DU CHAUFFAGE.
W385-1977 / A
CERTIFIED FOR
CERTIFIEE POUR
CANADA USA
IR3GN
IR3GP
CIR3GN
CIR3GP
MODEL
C E R T I F I E D
REFERENCE #161746
NATURAL GAS/GAZ NATUREL
PROPANE
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT
AVEC DES FILTRES À AIR.UTILISER AVEC LES PORTES VITRÉES
HOMOLOGUÉES AVEC CETTE UNITÉ SEULEMENT. UN COMBUSTIBLE SOLIDE
NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL.
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
THIS VENTED GAS FIREPLACE IS NOT FOR USE WITH AIR FILTERS. FOR
USE WITH GLASS DOORS CERTIFIED FOR THIS UNIT ONLY. NOT FOR USE
WITH SOLID FUEL.
ELECTRICAL RATING
:
115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNER’S
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
WARNING:
FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE ONLY. THE MINIMUM
FIREPLACE SIZE IS: HEIGHT 20.5”, DEPTH 13.25”, WIDTH 29”. THE MINIMUM INSIDE FLUE SIZE IS 6”. THE
MINIMUM DISTANCE FROM THE BOTTOM OF A COMBUSTIBLE MANTEL PROJECTING A MAXIMUM 3” FROM
THE WALL TO THE TOP OF THE UNIT IS 12”. SEE OWNER’S MANUAL FOR GREATER EXTENSIONS.
OPTIONAL FAN KIT - GZ550-KT, GD65
.
CLASS
:
115V, 1.5AMP, 60HZ
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPRE A WOLF STEEL. REFERER AU MANUEL
D’INSTALLATION DE PROPRIETAIRE POUR L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER
L’EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D’AIR.
ATTENTION
:
POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE. LES DIMENSIONS MINIMUMS SONT: HAUTER
19.75”, PROFONDEUR 13.25”, LARGEUR 29” LE DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 6”. LA
DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE
LA GARNITURE NORMALE EST 12”. REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES
.
SOUFFLERIE OPTIONELLE GZ550-KT, GD65.
4500FT (0-1370m)
ALTITUDE/ELEVATION
4500FT (0-1370m)
24,000 BTU/h
INPUT/ALIMENTATION
24,000 BTU/h
15,000 BTU/h
REDUCED INPUT/ALIMENTATION REDUITE
17,000 BTU/h
MANIFOLD PRESSURE:
3.5” WATER COLUMN
PRESSION AU COLLECTEUR
:
3.5” D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE
:
4.5” WATER COLUMN
PRESSION D’ALIMENTATION MINIMALE
:
4.5” D’UNE COLONNE D’EAU
MAXIMUM SUPPLY PRESSURE:
7.0” WATER COLUMN
PERSSION D’ALIMENTATION MAXIMALE
:
7.0” D’UNE COLONNE D’EAU
P4: 64.2%
MANIFOLD PRESSURE:
10” WATER COLUMN
PRESSION AU COLLECTEUR:
10” D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE:
11” WATER COLUMN
PRESSION D’ALIMENTATION MINIMALE
:
11” D’UNE COLONNE D’EAU
MAXIMUM SUPPLY PRESSURE:
13” WATER COLUMN
PERSSION D’ALIMENTATION MAXIMALE
:
13” D’UNE COLONNE D’EAU
P4:
64.2%
NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES INDIVIDUS À RISQUE SONT À
PROXIMITÉ DU FOYER. FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION
DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ
POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION EST
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS
MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA, OU AUX ÉTATS-UNIS, SELON LA
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OÙ CETTE NORME DES ÉTATS-UNIS NE PEUT ÊTRE
APPLIQUÉE, SE RÉFÉRER À LA NORME RELATIVE AU CRITÈRE DE MESURES DE
SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURÉES, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A
.
POUR UNE
UTILISER AVEC BARRIÈRE
W010-3157.
SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE
TROUVENT DANS LE MANUEL D'INSTALLATION.
DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NEAR
THE FIREPLACE. DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM,
BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR
MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE
HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED
HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR
FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS,
SITES AND COMMUNITIES, ANSI / NFPA 501A
.
FOR USE WITH BARRIER
W010-3157. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN
THE
INSTALLATION MANUAL.
SAMPLE
SS
IN
URER
PPLIANCE
PL
3GP
PROP
CE F
ARRIE. ONTARIO L4M
ILTERS. FOR
LY. NOT FOR USE
WOLF STEEL VENT KITS. SEE OWNER’S
INSTALLATION AND RESEALING IS
ON-COMBUSTIBLE FIREPLACE ONLY. THE M
13.25”, WIDTH 29”. THE MINIMUM INSIDE
M OF A COMBUSTIBLE MANTEL PROJECT
IS 12”. SEE OWNER’S MANUAL FOR GREATER
5
.
LEVATION
4500FT
ENTATION
LIMENTATION REDUITE
LUMN
E D’EAU
ER COLUMN
OLONNE D’EAU
” WATER COL
NE COLONNE D’EA
P4: 64.2%
FOLD PR
10” WAT
PRESSION AU COLLECTEUR
MINIMUM S
PRESSI
MAXIMUM
PERSSION D’
4: 64.2%
SI DE
FOYER. F
CHAMBRE À
STALLATION DANS U
ORME AUX EXIGENCES DE
BILES ÉQUIPÉES AU GAZ, EN VIGU
RME DE SÉCURITÉ ET DE CONSTRUC
SECTION 3280. DANS LE CAS OÙ CE
UÉE, SE RÉFÉRER À LA NORME R
CONTRE L'INCENDIE POUR
RÉES, LES SITES ET L
ARRIÈRE
W010-3
MANUEL D
64.2%
IR3G