![Napoleon IR3GN Installation And Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/napoleon/ir3gn/ir3gn_installation-and-operating-instructions-manual_4212155006.webp)
6
W415-1355 / 10.01.14
EN
2.4 GENERAL
INFORMATION
4.1B
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
As long as the required clearance to combustibles is
maintained, the most desirable and benefi cial location
for an appliance is in the center of a building, thereby
allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the
room where the appliance is to be located should be considered. If possible, you should choose a location
where the vent will pass through the house without cutting a fl oor or roof joist.
If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
® (NFI) as NFI Gas
Specialists
www.nficertified.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
IR3G
NG
LP
Altitude (FT)
0-4,500
0-4,500
Max. Input (BTU/HR)
24,000
24,000
Max. Output (BTU/HR)
19,200
19,200
Effi ciency (w/the fan on)
80%
80%
A.F.U.E. (maximum value)
77%
77%
Min. Inlet Gas Supply Pressure
4.5" (11mb) Water
Column
11" (27mb) Water Column
Max. Inlet Gas Supply Pressure
7" (17mb) Water
Column
13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions)
3.5" (9mb) Water
Column
10" (25mb) Water Column