installation

2.0 installation

2.1 

levelling the appliance

!

WARNING

• 

Risk of fi re! Maintain specifi ed air space clearances to vent pipe and appliance.

Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning 
appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any 
repair work done by a qualifi ed person before installing the insert. Remove the existing appliance damper or lock 
into an open position. 

Using screws, attach the appliance warning tag to the inside 
of the fi rebox of the appliance into which the insert is being 
installed.

The sheet-metal parts of the appliance, in which the gas 
appliance insert is to be installed, must not be cut.

If the wood-burning factory-built appliance has no gas access 
hole(s) provided, an access hole of 1½ inch (38.1mm) or less 
may be drilled through the lower sides or bottom of the appliance in a proper workman like manner. This access 
hole must be plugged with non-combustible insulation after the gas supply line has been installed.

Ensure that existing chimney cleanouts fi t properly.

The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing appliance 
before installing the gas appliance insert.

Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners.

The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc. but 
these parts are not to be applied so as to have an airtight seal.

W385-0199

Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your 
installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the 
dimensions with the requirements listed in this manual. 

You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing 
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes, 
doors), 48” (121.9cm) of the front of the appliance. 

Inserts only:

 This appliance is equipped with levelling screws, level the appliance before installing into the fi nal 

position. Levelling the appliance will eliminate rocking or excessive noise when the fan is in operation. Once the 
appliance is level, move it partially into place to allow for all connections to be made. It is not practical to level the 
appliance once it has been installed. Determine the required depth prior to installing the appliance and adjust the 
levelling screws accordingly.

WARNING: 

THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A

GAS FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING
WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN
REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY
HAVING JURISDICTION.

ATTENTION: 

CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE

SEULEMENT COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE
POUR BRULER DU BOIS OU TOUT AUTRE COMBUSTIBLE SOLIDE, SANS
QUE TOUTES LES PIECES ORIGINALES AIENT ETE REMPLACEES ET QUE
LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES AYANT
JURIDICTION.

W385-0199

Summary of Contents for Inspiration ZC Series

Page 1: ...o not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas...

Page 2: ...burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children and...

Page 3: ...ease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in...

Page 4: ...3 6 aluminum extrusion trim kit installation 14 4 0 operation 15 5 0 adjustments 16 5 1 pilot burner adjustment 16 5 2 venturi adjustment 16 5 3 flame characteristics 17 5 4 restricting vertical vent...

Page 5: ...36 914mm 51 2 140mm 25 635mm 151 2 394mm 115 8 295mm 73 8 187mm 3 76mm EXHAUST AIR INLET 1 1 dimensions This appliance must be recessed into a vented noncombustible solid fuel burning fireplace prefab...

Page 6: ...he National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States Suitable for mobile home installation if installed in accordance with the current standard CAN CSA Z240MH Series for gas equipped mob...

Page 7: ...on propre Napoleon R f rez au manuel d installation pour les sp cifications d vacuation Il est n cessaire de bien r installer et resceller l vacuation apr s avoir executer l entretien du syst me de pr...

Page 8: ...etc but these parts are not to be applied so as to have an airtight seal W385 0199 Have an authorized dealer install the appliance If you install the appliance yourself have your dealer review your i...

Page 9: ...tter A OUTSIDE Slip the one end of a liner a minimum of 2 51mm over the sleeve of the air terminal Secure using 3 screws Then seal the joint and screw heads with high temperature sealant Mill Pac not...

Page 10: ...and secure If equipped with a flex connector the appliance is designed to accept a 1 2 13mm gas supply Without the connector it is designed to accept a 3 8 9 5mm gas supply The appliance is equipped w...

Page 11: ...rywall dust will penetrate into the blower bearings causing irreparable damage Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulti...

Page 12: ...fore door is removed turn the appliance off and wait until appliance is cool to the touch Doors are heavy and fragile so handle with care ONLY LOWER DOOR BRACKET ONLY A barrier designed to reduce the...

Page 13: ...ar the embers into pieces and place along the front row of ports covering all of the burner area in front of the logs Care should be taken to shred the embers into thin small irregular pieces as only...

Page 14: ...instructions are included with each kit If this appliance is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be...

Page 15: ...DBEFOREOPERATING POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER ATTENTION NE PAS ALLUMER SI DES ENFANTS OU D AUTRES INDIVIDUS RISQUE SONT PROXIMIT DU FOYER QUICONQUE NE RESPECTE PAS LA LETTRE LES...

Page 16: ...pilot adjustment ensure that the pilot assembly has not been painted If overspray or painting of the pilot assembly has occurred remove the paint from the pilot assembly or replace Fine emery cloth o...

Page 17: ...on ADD IMAGE HERE 5 4 restricting vertical vents Some vent configurations may display a very active flame If this appearance is not desirable the vent exit may be restricted using a restrictor plate B...

Page 18: ...burner 5 If your appliance is equipped with a safety barrier cleaning may be necessary due to excessive lint dust from carpeting pets etc simply vacuum using the brush attachment 6 If your appliance i...

Page 19: ...the blower and clean using a soft brush and vacuum Re assemble the various components in reverse order Inspect the relief system The appliance relieves through the main glass door or through the flaps...

Page 20: ...dealer distributor for replacement parts DO NOT SUBSTITUTE MATERIALS Vinegar based glass cleaners have demonstrated an ability to provide a clean streak free glass surface note Do not clean glass whe...

Page 21: ...nut and lock washer For thermodisc replacement Remove the Z shaped mounting bracket secured to the firebox wall to the left of the blower Remove the thermodisc from the bracket and replace 6 Replace t...

Page 22: ...ts can be ordered through your Authorized dealer distributor For warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts alw...

Page 23: ...W525 0021 Relief door rail X2 8 W660 0009 On Off switch 9 W660 0019 Variable speed switch 10 W080 0071 Thermodisc bracket 11 W690 0002 Thermodisc 12 W385 2010 Napoleon logo W010 1101 Relief door assem...

Page 24: ...Propane conversion kit 2 W100 0128 SER Pan burner 3 W456 0042 Burner orifice 42 4 W080 0450 Orifice bracket 5 W010 0798 Pilot assembly NG 6 W010 1763 Right side housing Ref No Part number Description...

Page 25: ...ear exactly as illustrated GIZTRM4 GIZTRM3 GIZT3K Ref No Part number Description 1 CISM A Cast Iron Black Surround 2 GIZTRM4 Textured Satin Black 4 Sided Aluminum Trim 3 4 5 GIZTRM3 Textured Satin Bla...

Page 26: ...n 1 2 3 4 5 Ref No Part number Description 6 7 8 9 10 GIZBP6 3 Black 3 Sided Flashing GIZBP6 4 Black 4 Sided Flashing FPZC __SB Surround Brushed Copper Stainless Steel Copper GI823KT Decorative Brick...

Page 27: ...S BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to specified opening see venturi adju...

Page 28: ...sen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch thermosta...

Page 29: ...t be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to the appliance combustion chamber heat exchanger plated trim or other components due to water weather d...

Page 30: ...2 07 18 EN 30 service history 11 0 service history Appliance Service History This appliance must be serviced annually depending on usage Date Dealer Name Service Technician Name Service Performed Spec...

Page 31: ...EN W415 1366 D 12 07 18 31 notes...

Page 32: ...TI IN NG G O OV VE ER R 4 40 0 Y YE EA AR RS S A A A O O O O O OF F F F F F H H H H H H H HO O O O O OM M M M ME E E E E C C CO OM M MF F FO OR RT T P PR RO OD DU UC CT TS S 7200 Route Transcanadienne...

Page 33: ...nce d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement...

Page 34: ...aux br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajus...

Page 35: ...eut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement De m me install...

Page 36: ...5 mise en place du logo 47 3 6 installation des moulures d extrusion en aluminium 47 4 0 fonctionnement 48 5 0 r glages 49 5 1 r glage de la veilleuse 49 5 2 r glage du venturi 49 5 3 caract ristique...

Page 37: ...mm 25 635mm 151 2 394mm 115 8 295mm 73 8 187mm 3 76mm CHAPPEMENT ADMISSION D AIR 1 1 dimensions Cet appareil ne doit tre encastr que dans un appareil combustion solide ventil incombustible pr fabriqu...

Page 38: ...n moins d tre un appareil avec une chambre de combustion scell e vacuation directe L installation doit se conformer aux codes locaux En l absence de codes locaux l installation doit tre conforme au Co...

Page 39: ...y after servicing the vent air intake system L appareil doit tre ventil l aide de l ensemble d vacuation propre Napoleon R f rez au manuel d installation pour les sp ci cations d vacuation Il est n ce...

Page 40: ...s W385 0199_B WARNING THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE...

Page 41: ...ra peut tre n cessaire d ajuster le volet d air primaire A L EXT RIEUR Faites glisser l extr mit de l une des gaines un minimum de 2 51mm par dessus le manchon de la terminaison Fixez l aide de 3 vis...

Page 42: ...un installateur quali Mettez l appareil en place et xez le Si l appareil est muni d un raccord exible celui ci est con u pour recevoir une conduite de gaz de 1 2 13mm Sans raccord exible l appareil e...

Page 43: ...calibre 16 1 5mm 60 pieds 18 3m 1calibre 8 1 2mm 40 pieds 12 2m D connectez les ls des bornes 1 et 3 du soupape de l interrupteur marche arr t et remplacez les par les ls de l interrupteur mural ther...

Page 44: ...gratign e Les mat riaux de fa ade ou de nition ne doivent jamais empi ter sur l ouverture de l appareil L assemblage de la porte est con us pour pivoter vers l avant de l vacuation d un surplus de pre...

Page 45: ...s d gagements aux mat riaux combustibles Avant d enlever la porte teignez l appareil et attendez que ce dernier soit froid au toucher Les portes sont lourdes et fragiles manipulez avec soin ONLY LOWER...

Page 46: ...mi re rang e des ori ces du br leur en couvrant toute la surface l avant des b ches Les braises devraient tre d chir es tr s soigneusement en petits morceaux minces irr guliers car seuls les c t s exp...

Page 47: ...avec chaque ensemble Si cet appareil est install dans un appareil bois d gagement z ro veuillez prendre note de cette pr caution toute ouverture de circulation d air peut tre recouverte avec un mat r...

Page 48: ...ETY READBEFOREOPERATING POUR VOTRE SECURITE LIRE AVANT DE FAIRE FONCTIONNER ATTENTION NE PAS ALLUMER SI DES ENFANTS OU D AUTRES INDIVIDUS RISQUE SONT PROXIMIT DU FOYER QUICONQUE NE RESPECTE PAS LA LET...

Page 49: ...ez pour des fuites en appliquant une solution d eau savonneuse Avant d effectuer le r glage de la veilleuse assurez vous que l assemblage de la veilleuse n a pas t peint S il y a des traces de peintu...

Page 50: ...Pliez le rabat vers le haut comme illustr Ceci diminuera la v locit des gaz de combustion ralentissant ainsi le mouvement de la amme et cr ant une apparence plus traditionnelle Il est important d eff...

Page 51: ...br leur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du bross...

Page 52: ...rez nettoyer le capteur de amme l aide d une morceau de de laine d acier ou un tampon r curage Scotch Brite a n de retirer toute trace d oxydation Nettoyez l assemblage du pilote l aide d un aspirateu...

Page 53: ...vec la porte ouverte peut causer une d coloration des pi ces plaqu es L emballage de protection sur les pi ces plaqu es s enl ve mieux lorsque l assemblage est temp rature ambiante ou lorsqu il est ch...

Page 54: ...emplacement du thermodisque Retirez le support en forme de Z qui est x sur le mur de la chambre de combustion gauche de la souf erie Retirez le thermodisque gauche de la souf erie Retirez le thermodis...

Page 55: ...es pi ces peuvent tre command es chez votre d taillant autoris Pour un remplacement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsque...

Page 56: ...r de celle illustr Pour les pi ces de rechange voir la section assemblage de la soupape B che du c t gauche GL 631 B che de l arri re GL 631 B che du c t droite GL 631 B che centrale GL 631 Ensemble d...

Page 57: ...8 SER Br leur plateau 3 W456 0042 Injecteur de veilleuse 42 4 W080 0450 Support de l injecteur du br leur 5 W010 0798 Assemblage de veilleuse GN 6 W010 1763 Bo tier du c t droite R f No de pi ce Descr...

Page 58: ...GIZT3K R f No de pi ce Description 1 CISM A Fa ade en fonte noire 2 GIZTRM4 3 GIZTRM3 4 GIZBRKT Support de xation pour fa ade 5 GIZT3K Moulures d extrusion en aluminium noir satin avec relief 4 c t s...

Page 59: ...e fond noire 3 c t s GIZBP6 4 Plaque de fond noire 4 c t s FPZC __SB Fa ade cuivre bross acier inoxydable noire GI823KT Panneaux d coratifs simili briques en ni pierre de sable PRPZC Panneaux r ecteur...

Page 60: ...ERREZ PAS TROP FORT V ri ez pour des fuites en appliquant une solution d eau savonneuse Le volet d air est mal r gl Voir la section r glage du venturi pour le r glage de l ouverture du volet d air Du...

Page 61: ...e et la connexion la borne de la soupape Remplacez le thermocouple Remplacez la soupape La soupape est d fecteuse Remplacez la soupape La veilleuse br le pas de gaz au br leur principal le bouton du g...

Page 62: ...riodes d humidit la condensation des produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de Napol on Durant les dix premi res ann es Napol on remplacera ou r parera les...

Page 63: ...historique d entretien FR 11 0 historique de service Historique de service de l appareil Cet appareil doit tre entretenu annuellement selon son usage Date D taillant Nom du Technicien Travail Effectu...

Page 64: ...S D DE E 4 40 0 A AN NS S D D E EXISTENCE C C C C C C CO O O O O O ON N N N N N N N NS S S S S SA A A A A AC C C CR R R R R S S L L LA A C CO ON NC CE EP PT TIO ON N D DE PR RODUITS DE CONFORT 7200 Ro...

Reviews: