W415-1427 / C / 06.05.19
EN
38
maintenance
A.
Turn off the electrical power and the gas supply to the appliance.
B.
Open the lower louvre control door, the two side doors and the fi re viewing door. Remove the logs.
C.
Remove the relief door assembly held on with 6 screws. Discard the gasket.
D.
Disconnect the two blower wires. Remove the blower bracket held on with 4 screws.
E.
Replace the blower using the existing bracket. When connecting the replacement blower, tighten the
screws without distorting the rubber grommets. Replace the bracket / blower assembly in the appliance.
F.
Reconnect the two wires. Hold the replacement gasket in place and reattach the relief door assembly.
Replace the logs. Close all doors.
G.
Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 minutes
after lighting the appliance and will run for approximately 30-45 minutes after the appliance has been turned off.
Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from
coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered
by the warranty policy.
9.2
replacement blower installation
P
I
P ILOT
N
O
L
O
T
H I
L O
FF
O
RELIEF DOOR
RELIEF DOOR GASKET
TWIN BLOWER
VARIABLE
SPEED SWITCH
BLOWER
THERMODISC
te
rre
noi
r
blan
c