1.0 

INTrOduCTION 

3

1.1 

WARRANTy 

4

1.2 

DIMENSIONS 

5

1.3 

GENERAL INSTRUCTIONS 

5

1.4 

GENERAL INFORMATION 

6

1.5 

MObILE hOME 

6

1.6 

ShIPPING bRACkET 

6

2.0 

INsTallaTION 

7

2.1 

COMbUSTION AND vENTILATION AIR PROvISIONS 

7

2.2 

DETERMINING CONFINED OR UNCONFINED SPACE 

8

2.3 

GAS INSTALLATION 

9

2.4 

ELECTRICAL CONNECTION 

9

3.0 

fINIshINg 

10

3.1 

CAST FRONT INSTALLATION 

10

3.2 

LOG PLACEMENT 

10

3.3 

LOGO PLACEMENT 

11

4.0 

blOwEr INsTallaTION 

12

5.0 

OPEraTION  

13

6.0 

maINTENaNCE 

13

6.1 

OXyGEN DEPLETION SENSOR PILOT CLEANING 

14

7.0 

adjusTmENT 

14

7.1 

vENTURI ADJUSTMENT 

14

8.0 

rEPlaCEmENTs 

15

9.0 

TrOublE shOOTINg 

17

10.0  sErvICE hIsTOry 

19

11.0 

NOTEs 

20

2

W415-0204 / F / 10.23.08

Summary of Contents for GVFS60-N

Page 1: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supp...

Page 2: ...d ventilation air provisions 7 2 2 determining confined or unconfined space 8 2 3 Gas installation 9 2 4 electrical connection 9 3 0 finishing 10 3 1 cast front installation 10 3 2 log placement 10 3...

Page 3: ...screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the heater It is imperative that the control compartments burners...

Page 4: ...aused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scrat...

Page 5: ...Fuel Gas Code ANSI Z223 1 Installation Code which can be obtained from American Nation Standards Institute Inc or National Fire Protection Association Inc 1430 Broadway Batterymarch Park New York NY 1...

Page 6: ...ter column for propane No external electricity 110 volts or 24 volts is required for the gas system operation Expansion contraction noises during heating up and cooling down cycles are normal and are...

Page 7: ...K WALL BACK WALL ALCOVE A C A A B B 45 D OBJECT figure 2 0c figure 2 0b figure 2 0a 2 1 Combustion and ventilation air provisions This heater shall not be installed in a confined space or unusually ti...

Page 8: ...added on openable windows and doors and C Caulking or sealants are applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wal...

Page 9: ...ode 4 When connecting the gas line to the valve support the valve and ensure not to kink the line 5 Check for gas leaks by brushing on a soap and water solution DO NOT USE OPEN FLAME WARNING Do not co...

Page 10: ...on 3 2 log placement Blocked burner ports can cause an incorrect flame pattern carbon deposits and delayed ignition Phazertm logs glow when exposed to direct flame and provide a unique and realistic g...

Page 11: ...xposed to direct flame however care should be taken to not block the burner ports Blocked ports can cause an incorrect flame pattern carbon deposits and delayed ignition Replacement loose material mus...

Page 12: ...e blower housing 4 0 6 Remove the 2 screws from the side of the blower housing that you want the switch to be located on and re secure the on off switch Because the blower is thermally activated when...

Page 13: ...nite burner K Turn on all electric power to the fireplace A Turn off all electric power to the fireplace if service is to be performed B Push in gas control knob slightly and turn clockwise to off Do...

Page 14: ...oting Guide Carbon can be distributed in surrounding living area if the air shutter is improperly adjusted WARNING This procedure must be performed by a qualified service person Inspect the pilot for...

Page 15: ...ically approved with this appliance may result in property damage or personal injury WARNING COMPONENTS REF PART NO DESCRIPTION 1 W725 0030 SIT VALVE NG 1 W725 0031 SIT VALVE LP 2 W010 0757 BURNER 3 W...

Page 16: ...T BLOWER KIT 29 GS830 G GOLD TRIVET 29 GS830 C CHROME TRIVET 30 W550 0001 CHARCOAL EMBERS 31 W380 0002 VARIABLE SPEED SWITCH KNOB 32 KB 35 VARIABLE SPEED SWITCH 33 F_E EARLY AMERICAN FRONT 34 F_P PANO...

Page 17: ...e to connect length or wire gauge Replace Open window or door Use one of the methods described in ANSI Z223 1 Section 5 3 or the applicable local code Fill the tank Service or replace Oxygen Depletion...

Page 18: ...HI Gauge should read 7 minimum 4 5 water column for natural gas or 13 11 minimum water column for propane Outlet pressure can be checked the same as above using screw B Check with burner operating on...

Page 19: ...ervice History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name 10 0 service history 19 W415 0204 F 10 23 08 TP SERV...

Page 20: ...NOTES 11 0 notes 20 W415 0204 F 10 23 08 TP NOTES...