12
WS-415-131 / A / 09.11.00
LIGHTING INSTRUCTIONS
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is depressed.
1.
STOP! Read the above safety information on this la-
bel.
2.
Set the thermostat to lowest setting.
3.
Turn off all electric power to the fireplace.
4.
Open the control door. Turn the gas knob clockwise
to off.
5.
Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor, STOP! Follow "B" in the
above safety information on this label. If you don't smell
gas go to the next step.
6.
Find pilot located in front of the back log.
7.
Turn gas knob counter-clockwise
to pilot.
8.
Depress and hold gas knob while lighting the pilot
A.
This fireplace is equipped with a pilot which must be
lit by hand while following these instructions exactly.
B.
Before operating smell all around the fireplace area
for gas and next to the floor because some gas is
heavier than air and will settle on the floor.
C.
Use only your hand to push in and turn the gas control
knob. Never use tools. If the knob will not push in and
turn by hand, do not try to repair it. Call a qualified
service technician. Force or attempted repair may re-
sult in a fire or explosion.
D.
Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
GAS KNOB
OXYGEN DEPLETION SENSOR
OPERATION / MAINTENANCE
OPERATING INSTRUCTIONS
If heater shuts off, do not relight until you provide
fresh air. If heater keeps shutting off, have it serv-
iced. Keep burner and control compartment clean.
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again.
After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles burning off. In both cases, open a window to suf-
ficiently ventilate the room.
P
I
N
O
L
O
T
FF
O
with the push button igniter. Keep knob fully depressed
for one minute, then release. If pilot does not continue
to burn repeat steps 3 through 7.
9.
With pilot lit, turn gas knob counter-clockwise
to
on.
10.
If equipped with remote on-off switch, main burner
may not come on when you turn the valve to on. Re-
mote switch must be in the on position to ignite burner.
11.
Turn on all electric power to the fireplace.
TO TURN OFF GAS
1.
Turn off all electric power to the fireplace if service is to
be performed.
2.
Push in gas control knob slightly and turn clock-
wise
to off. Do not force.
OT
PIL
LO
IH
T
P
I
L
O
N
O
FF
O
GAS KNOB AT OFF