SAFETY INFORMATION

- Do not store or use gasoline or other 

fl ammable vapors and liquids in the vicinity of this 

or any other appliance.

- An LP-cylinder not connected for use shall not be 

stored in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

:

• Do not try to light any appliance.

• Shut off gas to the appliance.

• Extinguish any open fl ame.

• If odour continues, leave the area immediately.

• Do not touch any electrical switch; do not use 

any phone in your building.

• Immediately call your gas supplier from a neigh-

bour’s phone. Follow the gas supplier’s  instruc-

tions.

• If you cannot reach your gas supplier, call the fi re 

department.

Failure to follow these instructions could result in 

fi re or explosion, which could cause property dam-

age, personal injury, or death.

- Installation and service must be performed 

by a qualifi ed installer, service agency, or the 

gas supplier.

This appliance is only for use with the type of gas  
indicated  on  the  rating  plate.  This  appliance  is 
not convertible for use with other gases, unless a 
certifi ed kit is used. 

If the information in these instructions are not 
followed exactly, a fi re or explosion may result 
causing  property  damage,  personal  injury  or 
loss of life. Read the installation, operating and 
maintenance  instructions  thoroughly  before 
installing or servicing this equipment.

WARNING

!

INSTALLER: 

Leave this manual with the appliance

CONSUMER: 

Retain this manual for future reference

Summary of Contents for GSS42CFN

Page 1: ...se any phone in your building Immediately call your gas supplier from a neigh bour s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the re department Failure...

Page 2: ...W415 2975 09 02 21 EN 2 safety information...

Page 3: ...d be carefully supervised when they are in the same room as the appliance Toddlers young children and others may be susceptible to accidental contact burns A physical barrier is recommended if there a...

Page 4: ...tible materials to overheat and catch re Carbon monoxide poisoning may lead to death early signs of carbon monoxide poisoning resemble the u with headache dizziness and or nausea If you have these sig...

Page 5: ...1 log placement 17 8 2 glowing embers optional 18 8 3 charcoal lumps lava rock 18 8 4 optional front installation 18 8 5 logo placement 19 8 6 minimum mantel clearances 19 9 0 optional remote installa...

Page 6: ...sure opening when not in use This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used...

Page 7: ...t apply to your area for example in Massachusetts State The appliance off valve must be a T handle gas cock The exible connector must not be longer than 36 91 4cm The installation must conform with lo...

Page 8: ...n 1 4 rating plate information 1 5 dimensions This illustration is for reference only Refer to the rating plate on the appliance for accurate information note The rating plate must remain with the app...

Page 9: ...able Any enclosure shelter in which the appliance is used must comply with one of the following With walls on all sides but at least one permanent opening at ground level and no overhead cover Fig 1 2...

Page 10: ...terials in a vertical tube furnace at 1382 F 750 C and UL763 shall be considered non combustible materials Minimum clearance to combusibles must be maintained or a serious re hazard could result The a...

Page 11: ...for the top and two steel studs on the sides Finishing 1 25mm to back and sides Non combustible nishing 18 45 7cm to top 4 102mm to sides of appliance opening Non combustible nishing material ie cemen...

Page 12: ...N 12 framing 3 3 minimum enclosure clearances This appliance requires a minimum enclosure height of 58 1 2 148 6cm For temperature requirements the enclosure space around and above the appliance must...

Page 13: ...op of appliance An outdoor sealant must be used along the edge of the appliance and the non combustible material to keep water from entering the chase Use only non combustible material such as cement...

Page 14: ...r before closing the door Ensure adequate ventilation For gas and electrical locations see dimensions section All gas connections must be contained within the appliance when complete High pressure wil...

Page 15: ...peat steps E through I J With pilot lit turn gas knob counter clockwise to the ON position K If equipped with the ame adjustment valve push and turn the knob to high L Turn on all electrical power to...

Page 16: ...face position the framework to accommodate the thickness of the nished surface Bend out the six nailing tabs attached on top and on either side of the appliance and secure to the 2x4 framing The tabs...

Page 17: ...ers for a maximum glowing effect Log colours may vary During the initial use of the appliance the colours will become more uniform as colour pigments burn in during the heat activated curing process 8...

Page 18: ...ts can cause an incorrect ame pattern carbon deposits and delayed ignition PHAZER logs glow when exposed to direct ame Use only certi ed glowing embers and PHAZER logs available from your local author...

Page 19: ...7mm in from the left side as shown Risk of re Maintain speci ed air space clearances to combustibles Failure to comply with these instructions may cause a re or cause the appliance to overheat Ensure...

Page 20: ...h batteries installed through the opening in the faceplate and into the receiver The battery pack is secured and released with a catch mechanism Push the receiver into the catch to secure D Insert the...

Page 21: ...2 21 21 10 0 adjustment 10 1 venturi adjustment 10 2 ame characteristics VENTURI ADJUSTMENT CHART NG 1 8 3 2mm P 1 4 6 4mm Carbon can be distributed in surrounding living area if the air shutter is im...

Page 22: ...iquids The ow of combustion and ventilation air must not be obstructed 1 In order to properly clean the burner and pilot assembly remove the logs rocks and or glass to ex pose both assemblies 2 Keep t...

Page 23: ...replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of appliance Instal...

Page 24: ...W415 2975 09 02 21 EN 24 replacement parts...

Page 25: ...EN W415 2975 09 02 21 25 13 0 accessories...

Page 26: ...MLY TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustment section C a rb o nisb ein g d e...

Page 27: ...faulty Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI wall switch...

Page 28: ...ty does not cover damages resulting from the use of components not supplied with the appliance or the use of fuel other than those speci ed Any damages to appliance due to weather long periods of damp...

Page 29: ...EN W415 2975 09 02 21 29 16 0 service history...

Page 30: ......

Page 31: ...uble Appelez imm diatement votre fournisseur de gaz d un t l phone voisin Suivez ses instructions Si vous ne pouvez pas rejoindre votre fournisseur de gaz appelez le service des incendies Le non respe...

Page 32: ...W415 2975 09 02 21 32 FR consignes de s curit...

Page 33: ...enflamment Les jeunes enfants doivent tre surveill s attentivement lorsqu ils sont dans la m me pi ce que l appareil Les jeunes enfants et autres personnes risque sont sujets aux br lures accidentelle...

Page 34: ...g ne sd u neinto xic a tio n a um o n o xyd ed eca rb o n eresse m b le nt lag rip p e a vecc p h al e s ve rtig e se t o ud esn au s e s S i vo us p r se ntezc e ssig n e s l ap p are il p eu t n ep...

Page 35: ...1 installation de l interrupteur mural optionnel 44 5 0 installation du gaz 44 6 0 fonctionnement 45 7 0 supports de fixation 46 8 0 finitions 47 8 1 disposition des b ches 47 8 2 braises incandescen...

Page 36: ...est con u pour fonctionner avec le type de combustible indiqu sur la plaque d homologation Cet appareil ne peut tre converti un autre type de combustible moins d utiliser un ensemble de conversion ce...

Page 37: ...se prolongeant sur toute la largeur et la profondeur Les combustible solides ne doivent pas tre br l s dans cet appareil CET APPAREIL AU GAZ DEVRAIT TRE INSTALL ET ENTRETENU PAR UN INSTALLATEUR QUALI...

Page 38: ...sur la plaque d homologation Cette illustration est titre de r f rence seulement Consultez la plaque d homologation pour obtenir l information pr cise NOTE La plaque d homologation doit rester avec l...

Page 39: ...TE Lorsque vous choisissez un emplacement pour votre l appareil prenez soin d viter les endroits trop humides ou proximit de sources d eau courantes Toute enceinte abri dans laquelle l appareil est ut...

Page 40: ...s mat riaux dans une fournaise avec tube vertical 1382 F 750 C et la norme UL763 sont consid r s comme tant des mat riaux non combustibles A n d viter un risque d incendie les d gagements minimaux aux...

Page 41: ...re et sur les c t s Ossature incombustible 18 45 7cm du dessus 4 102mm sur les c t s de l ouverture de l appareil Des mat riaux de nition incombustibles p ex panneau de ciment brique pierre tuile peuv...

Page 42: ...s minimaux de l enceinte L enceinte de l appareil doit avoir une hauteur minimale de 58 1 2 148 6cm A n de respecter les contraintes de temp rature l espace l int rieur de l enceinte autour de l appar...

Page 43: ...us devez appliquer un scellant pour l ext rieur tout autour de l appareil et le long des mat riaux incombustibles Lorsque vous faites la nition jusqu l appareil n utilisez qu un mat riau incombustible...

Page 44: ...3 8 9 5mm L appareil est muni d une soupape d arr t manuelle pour fermer l alimentation en gaz Branchez le gaz en conformit avec les codes locaux En l absence de codes locaux l installation doit tre c...

Page 45: ...a n t u n em in u te p u isre l c h e z le S i lave ille u sen ere s tep a sa llu m e r p te zle s ta p e sE I J L o rsq u elav e ille u s ee s t a llu m e e n fo n c e ze t to u rn e zleb o u to nd...

Page 46: ...tants d ossature de fa on pr voir l paisseur de la surface nie D pliez les six supports de xation qui se trouvent sur le dessus et de chaque c t de l appareil et xez les aux 2x4 Les supports de xation...

Page 47: ...vous de positionner la b che de fa on ce que son encoche d gage bien les ori ces du br leur C Placez l extr mit de la b che crois W135 0672 droite du noeud de b che A La fourche de la b che devrait co...

Page 48: ...r les ori ces du br leur Le blocage des ori ces du br leur peut cr er une amme irr guli re des d p ts de carbone et un retard d allumage Les b ches PHAZERMD rougeoient lorsqu elles sont expos es une a...

Page 49: ...rvez tous les d gagements aux mat riaux combustibles sp ci s Incapacit de se conformer ces instructions peut causer un incendie ou une surchauffe Assurez vous que tous les d gagements arri re c t s de...

Page 50: ...le bloc de batteries dans l ouverture de la plaque puis glissez le dans le r cepteur La bo te de batteries est retenu en place par un m canisme de loquet Pour xer le bloc de batteries poussez le dans...

Page 51: ...ons FR 10 0 r glages 10 1 r glage du venturi 10 2 caract ristiques de la amme R GLAGE DU VENTURI GN 1 8 3 2mm P 1 4 6 4mm Du carbone peut se d poser dans des endroits de s jour avoisinants si le volet...

Page 52: ...re 7 Remettez en place les b ches les roches ou la vitre nettoy es si quip Omettre de positionner les composants d coratifs ad quatement peut causer des d pots de carbone qui peuvent se d poser l int...

Page 53: ...es pi ces peuvent tre command es chez votre d taillant autoris Pour un remplacement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsque...

Page 54: ...W415 2975 09 02 21 54 FR pi ces de rechange...

Page 55: ...W415 2975 09 02 21 55 pi ces de rechange FR 13 0 accessoires...

Page 56: ...rincipal le bouton du gaz est HI l interrupteur mural thermostat est ON Le thermostat ou l interrupteur sont d fectueux Reliez un l de d rivation entre les bornes de l interrupteur mural si le br leur...

Page 57: ...iquant une solution d eau savonneuse Du carbone se d pose sur les b ches ou les parois de la chambre de combustion Le volet d air est bloqu Assurez vous que l ouverture du volet d air n est pas bloqu...

Page 58: ...il par les intemp ries de longues p riodes d humidit la condensation les produits chimiques ou produits d entretien nuisibles ne seront pas la responsabilit de NAPOL ON La facture ou sa copie sera req...

Page 59: ...W415 2975 09 02 21 59 pi ces de rechange FR 16 0 historique d entretien...