Failure to follow these instructions could result in property damage, personal injury or
death.
The grills electrical systems are pre assembled in an electrical box which must be mounted a minimum
of 4” (102 mm) below the bottom of the grill as illustrated. Fasten the electrical box to the inside of the
enclosure, making sure the ventilation holes are not obstructed.
Plug the power supply into a Ground Fault Interrupter (GFI) protected circuit. Never remove the ground
-
ing plug or use with an adapter of 2 prongs.
!
4” (102mm) minimum, bottom
of the grill to top of the electrical
panel.
8” (203mm)
maximum
7”
(178mm)
9⅝”
(244mm)
LOCATED INSIDE CABINET
GFI Outlet
x1
x2
1
2
Summary of Contents for BIPRO665RBSS-3
Page 20: ...20 EN www napoleon com N415 0542 JUL 17 20...
Page 23: ...23 EN www napoleon com N415 0542 JUL 17 20 COUNTER TOP REQD NOT INCLUDED IM UGC665...
Page 25: ...25 EN www napoleon com N415 0542 JUL 17 20 x1 x1 x2 x1 5 LOCATED INSIDE CABINET 6 7...
Page 26: ...26 EN www napoleon com N415 0542 JUL 17 20 3 1 2...
Page 27: ...27 EN www napoleon com N415 0542 JUL 17 20...
Page 30: ...30 EN www napoleon com N415 0542 JUL 17 20...
Page 52: ...52 FR www napoleon com N415 0542 JUL 17 20...
Page 54: ...54 FR www napoleon com N415 0542 JUL 17 20 x1 x1 x1 4 3 5 SITU L INT RIEUR DU CABINET...
Page 55: ...55 FR www napoleon com N415 0542 JUL 17 20 Comptoir du haut requis NON INCLUS IM UGC665...
Page 57: ...57 FR www napoleon com N415 0542 JUL 17 20 x1 x1 x2 x1 5 6 7 SITU L INT RIEUR DU CABINET...
Page 58: ...58 FR www napoleon com N415 0542 JUL 17 20 3 1 2...
Page 59: ...59 FR www napoleon com N415 0542 JUL 17 20...
Page 67: ......
Page 68: ...N415 0542...