12
EN
www.napoleon.com
N415-0542 JUL 17.20
WARNING!
Always wear protective gloves and safety glasses when cleaning your grill.
WARNING!
Turn off the gas at the source and disconnect the unit before servicing. To avoid the
possibility of burns, maintenance should be done only when the grill is cool. A leak test must be
performed annually and whenever any component of the gas train is replaced or gas smell is present.
Maintenance Instructions
Combustion Air Adjustment
: (This must be done by a qualified gas installer.) The air shutter is factory set
and should not need adjusting under normal conditions. Under extreme field conditions, adjustments
might be required. When the air shutter is adjusted correctly the flames will be dark blue, tipped with
light blue and occasionally yellow.
•
With too little air flow to the burner, the flames are lazy yellow and can produce soot.
•
With too much air flow, the flames lift erratically and can cause difficulties when lighting.
Adjusting the air shutter:
1. Remove cooking grids and sear plates and leave lid open. You may have to open the door or remove
the top drawer (if equipped) to access the air-shutter screw located at the mouth of the burner. The back
cover must be removed for rear tube burner air shutter adjustment.
2. Loosen air-shutter lock screw and open or close air shutter as required. The normal opening settings
are:
Main Tube Burner
Propane 1/2” (13mm)
Rear Tube Burner
Propane Full Open
Natural 3/8” (10mm)
Natural 1/8” (3mm)
Smoker Burner
Propane 1/8” (3mm)
Natural 1/16” (1.6mm)
*Infra-Red burners have no air adjustment.
3. Light the burners and set to high. Visually inspect burner flames. When the shutters are set correctly,
turn burners off, tighten locking screws, and replace removed parts. Ensure that the insect screens are
installed.
We recommend this gas grill be thoroughly inspected and serviced annually by a qualified service person.
At all times keep the gas grill area free from combustible materials, gasoline and other flammable vapors
and liquids. Do not obstruct the flow of ventilation and combustion air.
Light Blue
Yellow Tipping
Dark Blue
Burner
Burner Port
Approximately
1/2” (13mm)
!
Summary of Contents for BIPRO665RBSS-3
Page 20: ...20 EN www napoleon com N415 0542 JUL 17 20...
Page 23: ...23 EN www napoleon com N415 0542 JUL 17 20 COUNTER TOP REQD NOT INCLUDED IM UGC665...
Page 25: ...25 EN www napoleon com N415 0542 JUL 17 20 x1 x1 x2 x1 5 LOCATED INSIDE CABINET 6 7...
Page 26: ...26 EN www napoleon com N415 0542 JUL 17 20 3 1 2...
Page 27: ...27 EN www napoleon com N415 0542 JUL 17 20...
Page 30: ...30 EN www napoleon com N415 0542 JUL 17 20...
Page 52: ...52 FR www napoleon com N415 0542 JUL 17 20...
Page 54: ...54 FR www napoleon com N415 0542 JUL 17 20 x1 x1 x1 4 3 5 SITU L INT RIEUR DU CABINET...
Page 55: ...55 FR www napoleon com N415 0542 JUL 17 20 Comptoir du haut requis NON INCLUS IM UGC665...
Page 57: ...57 FR www napoleon com N415 0542 JUL 17 20 x1 x1 x2 x1 5 6 7 SITU L INT RIEUR DU CABINET...
Page 58: ...58 FR www napoleon com N415 0542 JUL 17 20 3 1 2...
Page 59: ...59 FR www napoleon com N415 0542 JUL 17 20...
Page 67: ......
Page 68: ...N415 0542...