Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing
: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak
Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Care department and have the grill inspected by a certified gas
installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
Summary of Contents for BIP500RB
Page 20: ...www napoleongrills com 20 EN REAR BURNER MODEL ONLY ...
Page 23: ...www napoleongrills com 23 EN BIP500 ...
Page 29: ...www napoleongrills com 29 EN ...
Page 30: ...www napoleongrills com 30 EN NOTES ...
Page 50: ...www napoleongrills com 50 FR Arrière Brûleur Seulement ...
Page 53: ...www napoleongrills com 53 FR BIP500 ...
Page 59: ...www napoleongrills com 59 FR ...
Page 60: ...N415 0253 ...