![Napoleon BILEX 485 Manual Download Page 6](http://html1.mh-extra.com/html/napoleon/bilex-485/bilex-485_manual_3419440006.webp)
6
EN
www.napoleongrills.com
N415-0434CE-GB-DE OCT 23.17
The installation must comply with national and regional codes. The gas supply pipe must be sufficiently
sized to supply the kW input specified on the rating plate, based on the length of the piping run. If
installing a side burner, a separate line must be branched off to the side burner unit and enter the side
burner opening at the specified location. If the enclosure is to house a propane cylinder, the tank portion
of the enclosure must be ventilated according to local codes, and must not have communication with the
cavity used to enclose the gas grill. A propane cylinder can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must
have both of the following:
1. At least one unobstructed ventilation opening on the exposed exterior side of the enclosure located
within 127mm of the top of the enclosure. The opening must have a total free area of more than 130 cm
2
for a cylinder up to 9 kg and 195 cm
2
for a cylinder larger than 9 kg.
2. At least one ventilation opening on the exposed, exterior side of the enclosure located 25.4 mm or less
from the floor level. The opening must have a total free area of more than 65 cm
2
for a cylinder up to 9 kg
and 100 cm
2
for a for a cylinder larger than 9 kg. The upper edge must be no more than 127 mm above
the floor level.
Every opening must be large enough to permit the entrance of a 3.2 mm rod.
WARNING!
•
The cylinder valve(s) must be readily accessible for hand operation. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without
the use of tools.
• The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiation, a flame barrier, and protection from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
•
There must be a minimum clearance of 51 mm between the floor of the LP-gas cylinder enclosure
and the ground.
• The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and
the connections inspected and tested outside the cylinder enclosure. Any connections that can
be disturbed when installing the cylinder in the enclosure must be accessible for testing inside the
enclosure.
CYLINDER SIZE
OPENING A AREA OPENING B AREA
Up to 9 kg
130 cm
2
65 cm
2
Larger than 9 kg
195 cm
2
100 cm
2
127mm
MAXIMUM
25.4mm
MAXIMUM
OPENING
A
OPENING
B
51mm
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
864mm
RECOMMENDED
127mm
MAXIMUM
Summary of Contents for BILEX 485
Page 20: ...20 EN www napoleongrills com N415 0434CE GB DE OCT 23 17...
Page 26: ...26 EN www napoleongrills com N415 0434CE GB DE OCT 23 17 Notes...
Page 47: ...47 DE www napoleongrills com N415 0434CE GB DE OCT 23 17...
Page 53: ...53 DE www napoleongrills com N415 0434CE GB DE OCT 23 17 Notes...
Page 54: ...54 DE www napoleongrills com N415 0434CE GB DE OCT 23 17 Notes...
Page 55: ...55 DE www napoleongrills com N415 0434CE GB DE OCT 23 17 Notes...