4.

 Position the notch located on the end of the center log

(#5) against the middle grate post with the other end of the
log resting in the pocket of the left crossover log.

5.

 Place the bottom of the right crossover log (#6) against

the right firebox side and pulled forward to the grate. The
top of the log should rest in the pocket provided on the
center log (#5).

PHAZER

TM

 logs and glowing embers exclusive to Napoleon Fire-

places, provide a unique and realistic glowing effect that is
different in every installation. Take the time to carefully po-
sition the glowing embers for a maximum glowing effect.
Log colours

 

may vary. During the initial use of the fireplace,

the colours will become more uniform as colour pigments
burn in during the heat activated curing process.

1.

 Place the back log (#1) onto the log

support tray and in front of the tabs. The
tabs maintain an air space between the
log and firebox back to facilitate combus-
tion air flow. Ensure that the back of the log
rests against the brackets on the back wall
of the firebox.

2.

 Move the two small logs (#2 & #3) into position, lining

up the studs located on the burner with the holes on the
bottom of the logs. Ensure that the small logs sit flat on the
burner.

3.

 Place the bottom of the left crossover log (#4) against

the left firebox side and pulled forward to the grate.
The top of the log should rest in the pocket on the back log.

LOG PLACEMENT

Randomly place the charcoal embers along the front and
sides of the log support tray in a realistic manner. 

Fine

dust found in the bottom of the bag should not be used.

Tear the embers into pieces and place along the front row
of ports covering all of the burner area in front of the small
logs (#2 & #3). Care should be taken to shred the embers
into thin, small irregular pieces as only the exposed edges
of the fibre hairs will glow. 

The ember material will only

glow when exposed to direct flame; however, care
should be taken to not block the burner ports.

Blocked burner ports can cause an incorrect flame pat-
tern, carbon deposits and delayed ignition. 

PHAZER

TM

 logs

glow when exposed to direct flame. Use only certified "glow-
ing embers" and 

PHAZER

TM

 logs available from your Na-

poleon  dealer.

Remove the backing of the
logo supplied and place on the
glass viewing door, as
indicated.

CHARCOAL EMBERS

GLOWING EMBERS

LOGO PLACEMENT

½"

½"

LOGO

FIGURE 19

FIGURE 18a-f

TAB

SIDEVIEW

Summary of Contents for BGNV36N

Page 1: ...ot store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 2: ...is fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediat...

Page 3: ...designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak and test fired at a quality test station The co...

Page 4: ...rviced by a qualified installer to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachus...

Page 5: ...temperature and acts as a safety shut off See A below It shuts down the gas to the main burner in the unlikely event of the unit overheating The HI Limit switch will automatically reset after the uni...

Page 6: ...is complete 1 Move the fireplace into position and secure using the nailing tabs and or secure to the floor through the 1 4 holes located at either end of the base 2 Route a 3 8 N P T black iron gas l...

Page 7: ...tab vertically on the cor ner post Figure 12 a Drill through the centre of the top and bottom slots in the nailing tab Secure using the two sheet metal screws supplied This allows the nailing tab to s...

Page 8: ...irebox using three screws DOOR LATCH UPPER LOUVRE FLANGE CLIP FIGURE13 LOWER LOUVRES VALVE CONTROLDOOR LOUVRE HOOD SLOT BRACKET FINISHING DOOR OPENING CLOSING GVFL LOUVRE INSTALLATION FIGURE14 FIGURE1...

Page 9: ...sition lining up the studs located on the burner with the holes on the bottom of the logs Ensure that the small logs sit flat on the burner 3 Place the bottom of the left crossover log 4 against the l...

Page 10: ...e taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not cov ered by the warranty policy A B INSTALLATION TO BE DONE...

Page 11: ...he current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States The wire harness provided in this kit is a universal har ness When installed e...

Page 12: ...fireplace 3 Turn the gas knob clockwise to off 4 Wait five 5 minutes to clear out any gas If you smell gas including near the floor Stop Follow B in the above safety information on this label If you d...

Page 13: ...ck to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on A 5 to 10 second total light up period is satisfactory If ignition takes longer consult...

Page 14: ...AL INSETS BLACK GOLD PLATED 39 HOIBC 1 HERITAGE ORNAMENTAL INSETS BRUSHED COPPER PLATED 39 HOIBG 1 HERITAGE ORNAMENTAL INSETS BRUSHED GOLD PLATED 40 DOIG 1 DIAMOND ORNAMENTAL INSETS GOLD PLATED 40 DOI...

Page 15: ...15 W415 0275 C 09 23 05...

Page 16: ...cked or disconnected Correct See Figure 2 Unit has overheated See Figure 2 Pilot goes out when the gas knob is re leased The gas valve has an interlock device which will not allow the pilot burner to...

Page 17: ...or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVERTORQUE Leak test with a soap and wa...

Page 18: ...18 W415 0275 C 09 23 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 19: ...19 W415 0275 C 09 23 05 NOTES...