Napoleon BGNV36N Installation And Operation Instructions Manual Download Page 14

14

W415-0275 / C / 09.23.05

#

PART NO. DESCRIPTION

1

W357-0001

PIEZO IGNITER

2

W680-0004

THERMOPILE

3

W680-0005

THERMOCOUPLE

4

W010-0764

BURNER

5

W010-0800

NATURAL GAS PILOT ASSEMBLY

5

W010-0801

PROPANE GAS PILOT ASSEMBLY

6

W660-0021

SAFETY SWITCH

7

W660-0007

HI LIMIT SWITCH

8*

W660-0005

ON/OFF TOGGLE SWITCH

9

W455-0069

NATURAL GAS PILOT INJECTOR

9

W455-0067

PROPANE GAS PILOT INJECTOR

10

W725-0025

NATURAL GAS VALVE

10

W725-0026

PROPANE GAS VALVE

11*

W385-0245

NAPOLEON LOGO

12*

GD660

STANDARD W ALL SWITCH & 20FT OF WIRE

13*

W225-0099

BLACK DOOR FRAME

14

W010-0856

GLASS c/w GASKET

15

W010-0857

BLACK DOOR C/W GLASS

16

W455-0048

#47  NATURAL GAS ORIFICE

16

W455-0047

#56  PROPANE GAS ORIFICE

17

GL-639

LOG SET

18

W361-0016

GLOWING EMBERS

19

W550-0001

CHARCOAL EMBERS

20

W135-0183

BACK LOG (#1)

21

W135-0184

LEFT MIDDLE LOG (#2)

22

W135-0185

RIGHT MIDDLE LOG (#3)

23

W135-0186

LEFT CROSSOVER LOG (#4)

24

W135-0187

MIDDLE CROSSOVER LOG (#5)

25

W135-0188

RIGHT CROSSOVER LOG (#6)

26

W010-0805

LOUVRE HOOD 

W

LOUVRE

 

BRACKETS

#

PART NO. DESCRIPTION

27*

W690-0001

MILLIVOLT THERMOSTAT

28*

W660-0010

REMOTE CONTROL - 

ADVANTAGE

28*

W660-0011

REMOTE CONTROL - 

ADVANTAGE

 

PLUS

29

GZ550-1KT

BLOWER KIT

30*

GD65

FAN KIT

31*

GD36

THERMOSTATIC SENSOR CONTROL KIT  

USE

 

WITH

 

GD

65 

ONLY

32*

W500-0033

VARIABLE SPEED SWITCH W ALL MOUNTING PLATE

33

GA-566

HOT AIR DISTRIBUTION KIT

34*

W690-0005

THERMOSTAT 110V 

FOR

 

USE

 

WITH

 GA-566

35

GA-72

HOT AIR EXHAUST KIT

36

GA-70

EXTENSION KIT 5

FT

37

GVFLK-1

LOUVRE KIT, UPPER & LOWER - 

BLACK

37

GVFLPB-1

LOUVRE KIT, UPPER & LOWER - 

POLISHED

 

BRASS

37

GVFLAB-1

LOUVRE KIT, UPPER & LOWER - 

ANTIQUE

 

BRASS

37

GVFLSS-1

LOUVRE KIT, UPPER & LOWER - 

BRUSHED

 

STAINLESS

 

STEEL

38

L36K

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

BLACK

39

HOIG-1

HERITAGE ORNAMENTAL INSETS - 

GOLD

 

PLATED

39

HOIKG-1

HERITAGE ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

39

HOIBC-1

HERITAGE ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

39

HOIBG-1

HERITAGE ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

40

DOIG-1

DIAMOND ORNAMENTAL INSETS - 

GOLD

 

PLATED

40

DOIKG-1

DIAMOND ORNAMENTAL INSETS- 

BLACK

 

GOLD

 

PLATED

40

DOIBC-1

DIAMOND ORNAMENTAL INSETS- 

BRUSHED

 

COPPER

 

PLATED

40

DOIBG-1

DIAMOND ORNAMENTAL INSETS- 

BRUSHED

 

GOLD

 

PLATED

41

GOIG-1

GOTHIC ORNAMENTAL INSETS - 

GOLD

 

PLATED

41

GOIKG-1

GOTHIC ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

41

GOIBC-1

GOTHIC ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

41

GOIBG-1

GOTHIC ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

42

SOIG-1

SEASHELL ORNAMENTAL INSETS - 

GOLD

 

PLATED

42

SOIKG-1

SEASHELL ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

42

SOIBC-1

SEASHELL ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

42

SOIBG-1

SEASHELL ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

43

EOIG-1

ECLIPSE ORNAMENTAL INSETS - 

GOLD

 

PLATED

43

EOIKG-1

ECLIPSE ORNAMENTAL INSETS - 

BLACK

 

GOLD

 

PLATED

43

EOIBC-1

ECLIPSE ORNAMENTAL INSETS - 

BRUSHED

 

COPPER

 

PLATED

43

EOIBG-1

ECLIPSE ORNAMENTAL INSETS - 

BRUSHED

 

GOLD

 

PLATED

44

DK36-R

DOOR KIT, RECTANGULAR - 

BLACK

44

DK36-RG

DOOR KIT, RECTANGULAR - 

GOLD

 

PLATED

45

DK36-A

DOOR KIT,  ARCHED - 

BLACK

45

DK36-AG

DOOR KIT, ARCHED - 

GOLD

 

PLATED

46

DK36-W

DOOR KIT, WEBBED - 

BLACK

46

DK36-WG

DOOR KIT, WEBBED - 

GOLD

 

PLATED

47*

W175-0159

FUEL CONVERSION KIT - 

NG

-

LP

47*

W175-0164

FUEL CONVERSION KIT - 

LP

-

NG

Contact your dealer or the factory for questions concerning
prices and policies on replacement parts. Normally all parts
can be ordered through your Napoleon dealer or distributor.

When ordering replacement parts always give the follow-
ing information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER

 

OF

 

FIREPLACE

2.  I

NSTALLATION

 

DATE

 

OF

 

FIREPLACE

3.  P

ART

 N

UMBER

4.  D

ESCRIPTION

 

OF

 

PART

5.  F

INISH

FOR

 

WARRANTY

 

REPLACEMENT

 

PARTS

A

 

PHOTOCOPY

 

OF

 

THE

ORIGINAL

 

INVOICE

 

WILL

 

BE

 

REQUIRED

 

TO

 

HONOUR

 

THE

 

CLAIM

.

REPLACEMENTS

REPLACEMENT PARTS

ACCESSORIES

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

 

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

 

DEALER

.

Summary of Contents for BGNV36N

Page 1: ...ot store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 2: ...is fireplace be modified This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance Do not use this fireplace if any part has been under water Immediat...

Page 3: ...designed with superior components and materials assembled by trained craftsmen who take great pride in their work The burner and valve assembly are leak and test fired at a quality test station The co...

Page 4: ...rviced by a qualified installer to conform with local codes Installation practices vary from region to region and it is important to know the specifics that apply to your area for example in Massachus...

Page 5: ...temperature and acts as a safety shut off See A below It shuts down the gas to the main burner in the unlikely event of the unit overheating The HI Limit switch will automatically reset after the uni...

Page 6: ...is complete 1 Move the fireplace into position and secure using the nailing tabs and or secure to the floor through the 1 4 holes located at either end of the base 2 Route a 3 8 N P T black iron gas l...

Page 7: ...tab vertically on the cor ner post Figure 12 a Drill through the centre of the top and bottom slots in the nailing tab Secure using the two sheet metal screws supplied This allows the nailing tab to s...

Page 8: ...irebox using three screws DOOR LATCH UPPER LOUVRE FLANGE CLIP FIGURE13 LOWER LOUVRES VALVE CONTROLDOOR LOUVRE HOOD SLOT BRACKET FINISHING DOOR OPENING CLOSING GVFL LOUVRE INSTALLATION FIGURE14 FIGURE1...

Page 9: ...sition lining up the studs located on the burner with the holes on the bottom of the logs Ensure that the small logs sit flat on the burner 3 Place the bottom of the left crossover log 4 against the l...

Page 10: ...e taken to prevent drywall dust from coming into contact with the blower or its compartment Any damage resulting from this condition is not cov ered by the warranty policy A B INSTALLATION TO BE DONE...

Page 11: ...he current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States The wire harness provided in this kit is a universal har ness When installed e...

Page 12: ...fireplace 3 Turn the gas knob clockwise to off 4 Wait five 5 minutes to clear out any gas If you smell gas including near the floor Stop Follow B in the above safety information on this label If you d...

Page 13: ...ck to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on A 5 to 10 second total light up period is satisfactory If ignition takes longer consult...

Page 14: ...AL INSETS BLACK GOLD PLATED 39 HOIBC 1 HERITAGE ORNAMENTAL INSETS BRUSHED COPPER PLATED 39 HOIBG 1 HERITAGE ORNAMENTAL INSETS BRUSHED GOLD PLATED 40 DOIG 1 DIAMOND ORNAMENTAL INSETS GOLD PLATED 40 DOI...

Page 15: ...15 W415 0275 C 09 23 05...

Page 16: ...cked or disconnected Correct See Figure 2 Unit has overheated See Figure 2 Pilot goes out when the gas knob is re leased The gas valve has an interlock device which will not allow the pilot burner to...

Page 17: ...or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL DO NOT OVERTORQUE Leak test with a soap and wa...

Page 18: ...18 W415 0275 C 09 23 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Page 19: ...19 W415 0275 C 09 23 05 NOTES...

Page 20: ...20 W415 0275 C 09 23 05 NOTES...