WI853C XP-400 Installation Instructions
Program User 4 Arm/Disarm Code.
Select reporting to Telco 1 [36-2] or Telco 3
[56-2].
[21]Keypad Features 2
(1) Audible Panic - Keypad Panic will not
turn the Bell on unless this option is pro-
grammed.
(2) Exit/Entry with Urgency - select to give
an audible indication of Exit and Entry times.
During the last 10 seconds of entry and exit
time, the keypad sounds a distinct sound to
indicate the premises must be left or the
panel must be disarmed.
(3) Display Bypassed (Armed) - Select to
display bypassed zones while the panel is
armed.
(4) Disable Code Entry Beeps - Program to
disable keypad beeping on valid code and
function entries.
[22]Miscellaneous Features 1
(1) Abort Delay - Program to allow a 15
second Delay (except
24 Hour Zones) after
a zone trip before reporting. Disarm the
system within 15 seconds to prevent report-
ing.
(2) Easy Exit/Easy Arm - Enables
command. While the system is armed,
entering this command allows 3 minutes to
Exit through
Exit/Entry and Exit/Entry Fol-
lower Zones. Enabling this option also
enables Easy Arm, enter
!
to arm
the system.
(3) Swinger Shutdown - Automatically dis-
ables armed zones with excessive alarm/
restores (swingers). Non-24-Hour Protec-
tion zones: allows only 3 alarms and 2
restores per zone per arming before the
zone is disabled.
(4) Bell on Line Cut (Armed) - Program to
turn the Bell Output on if the telephone line
has been cut while the panel is armed.
[23]Programmable Output Features 1
(1) Audio Verification - Program to acti-
vate the PGM during reporting. Select
specific zones for audio verification by pro-
gramming the required zones in
PGM Out-
put [08], PGM Features 2 [24] and PGM
Features 3 [25]. Connect the PGM to the
Veriphone
TM
trigger low input.
(2) Access Output - Activates the PGM
output for 5 seconds using the
com-
mand.
(3) Follow Keypad Sounder - The following
keypad sounds will activate the PGM output:
Entry Sounder, Keypad Pulsing Sounder,
Keypad Output on Alarm, Chime, Fault Find.
(4) Keyfob/Keyswitch Chirp - Program to
chirp the PGM Output (1) one time when the
panel is armed or (2) two times when the
panel is disarmed. Wire as shown in Figure
6.
[24]Programmable Output
Features 2
(1) Reserved
(2) AUX - Program to activate the PGM on a
AUX alarm.
N/O
N/C
COM
BLK
RED
+AUX
Siren Driver
Steady Input
PGM
+AUX
K1
FIGURE
6 K
EYFOB
/K
EYSWITCH
C
HIRP
Wi853c
page 14